Hearth and Home Technologies BH 105 manual Design

Page 7

Assembly

Refer to the illustration on page 3 to identify the compo- nents listed below:

1.Install the control board cover as well as the access cover located on the feeder cover.

2.Install the spring handles provided with the unit on the ash door, firebox door and the heat exchanger cleanout rod handles. (Fasten handles by turning them counterclockwise and pushing inward simultaneously).

3.Install 3/4” MPT boiler drain in the fitting as shown.

Note: Use pipe thread sealant or teflon tape on ALL threads before connections are made.

4.Install 3/4” MPT pressure relief valve as shown.

5.Install the 1/2” MPT aquastat well in fitting as shown, then place aquastat in the well and fasten with a zip tie. The aquastat sensor is located under the top sheet metal jacket.

6.Install the 1/2” MPT temperature/pressure gauge in fitting as shown.

7.Locate and install outside air temperature sensor. Loca- tion of this sensor should be on the north side of the home or building and out of direct sunlight. Use the cable supplied with the boiler to attach the sensor to the terminals located on the hopper. (Place at the back side just above and to the right of the main power connection box) The wires can be connected to the sensor with the connectors supplied. Wire nut or butt splice connectors could also be used. The con- nections at the boiler can be done with the two 1/4” female push on connectors supplied.

8.Fasten the conduit to the ash base with the clamps provided.

Design:

The first thing that needs to be done is deciding where and how the boiler will be installed.

Things that need to be taken into consideration are the intended use of the boiler for example, is the boiler going to be used as your primary heating system or is it going to be used as a secondary or backup heating system. If it is to be used in conjunction with an existing oil or gas boiler system will it be piped in parallel or in series? The answers to these and other questions can be determined by talking to your certified dealer or a qualified HVAC or plumbing contrac- tor. This will ensure that the boiler is installed and piped to accommodate your needs and expectations.

Consideration must be given to the venting as well as electrical and clearance requirements. (Clearances must be maintained to combustibles and also for service)

Make sure fans are not used in the fuel storage area, unless they are installed so as not to create a negative pressure in the room where the solid fuel burning appliance is located.

 

MINIMUM NON-COMBUSTIBLE FLOOR PROTECTION AREA

 

 

NON-COMBUSTIBLE

42" CANADA

 

FLOOR PROTECTOR

 

40"USA

 

55" USA & CAN

 

 

40" USA

42" CANADA

16" USA

18" CAN

 

 

55" USA & CAN

 

Floor Protection:

The striped area indicates the minimum required floor protec- tion area if the boiler is going to be placed on a combustible floor. It requires 40” X 55”(US) or 42” X 55”(CAN) of non combustible floor protection as shown. 16”(US) or 18”(CAN) of the floor protection must be in front of the firebox door as shown. Floor protection must be a minimum of 26 gauge sheet metal. Floor protection must also be provided under any horizontal run of vent pipe equal to the outside diameter of the venting plus 2” to each side.

Example: 4” type “L” or “PL” vent pipe has an outside diam- eter of 4-1/2” + 2” on each side equals a protected floor area of 8-1/2” wide underneath the horizontal run.

7

Image 7
Contents BH 105 Pellet Boiler Installation & Operating ManualPage Parts Locations Introduction Table Of ContentsECO-CHOICE Limited Warranty WarrantyBoiler Kit Materials Refer to AssemblyDesign Installation is to be Performed by a Qualified Installer Venting Venting Venting Ventingti gKeep combustibles away From flue outlet Venting InstallationOutside Air Main Wiring Installation InstallingInstallationDuct Installing Duct/AirInstallationConditioning Example of Typical Tankless Domestic HOT Water Piping InstallationUnion AIR Vent Installation Power Failure / Heat Dissipation Loop Over Heat Safety ZoneTest Draft Test ProcedureFuel and Fuel Storage Fuel SpecificationsStatus Light OperationControl Board Operation Without the Outdoor Air Temperature Sensor InstalledPellet Boiler Outdoor Air Reset Operation Starting a Fire Automatically Turn Mode Selector to OFFMAX. Temp Flip the Igniter Switch up into the Auto positionHave matches or other ignition source ready Lighting a Fire ManuallyOperation To remove the feeder cover MaintenanceBurnpot Cleaning Feeder Chamber FigRemove Ash Pan Open Ash DoorCleaning Steps Combustion Blower Cleaning Helpful Hints TroubleshootingFuel Atmospheric Conversion Bh105 #8 Ash base Assembly Stocked at depot #28 Feeder Assembly #29 boiler Kit #30 water Plate Kit #31 handle Kit Description COmmENTS PArT NumbEr Hardware Packages BTU Input Range= 0, and 9350 to 113,900 SpecificationsElectrical 120 VAC 60 Hz Pellet Boiler Wiring Diagram DiagramPower Failure Backup Supply BH105 Testing LabelService Record / Notes Proudly Printed On 100% Recycled Paper Quick Reference Auto-Light Signature of Boxer

BH 105 specifications

Hearth and Home Technologies BH 105 is a modern and versatile fireplace that combines functionality and aesthetic appeal. Designed for both residential and commercial spaces, it brings the warmth of a traditional fireplace with the convenience of contemporary technology. One of the standout features of the BH 105 is its impressive heating capacity, efficiently warming larger areas while maintaining a cozy atmosphere.

The BH 105 uses advanced combustion technology, which not only maximizes heat output but also minimizes emissions, making it an eco-friendly choice for homeowners. This fireplace achieves a commendable efficiency rating, ensuring that most of the heat generated is utilized effectively, reducing energy costs and environmental impact.

Aesthetically, the BH 105 offers a sleek and contemporary design that can seamlessly blend with any decor. The large viewing area features tempered glass, providing unobstructed views of the mesmerizing flames. This visual aspect enhances the ambiance of any room, making it a focal point in the home. The fireplace is available in various finishes, allowing homeowners to choose a style that complements their personal taste and existing interior designs.

User experience is a priority in the BH 105’s design. It includes features such as an easy-to-use control panel and a programmable thermostat that allows for precise temperature regulation. This user-friendly interface enables individuals to set their desired comfort levels with ease.

The BH 105 also comes equipped with safety features like an automatic shut-off system, ensuring peace of mind for users, especially in households with children or pets. The durability of the materials used in its construction ensures that the fireplace can withstand the rigors of regular use while maintaining its aesthetic charm.

In summary, Hearth and Home Technologies BH 105 is a perfect embodiment of modern fireplace technology, offering high efficiency, stunning design, and user-friendly features. Whether for heating a living room or creating a cozy atmosphere in a commercial setting, the BH 105 stands out as an exceptional choice for discerning individuals seeking warmth without compromising on style.