GAS CONNECTION
Gas connection must be carried out according to the rules in force.
The manufacturing company release the unit, once tested, adjusted for the kind of gas stated on the rating plate located on the back of the range, next to connection pipe. Be sure that you are going to connect the unit to the same kind of gas written on the plate.
CONNECTION USING A RIGID PIPE OR A
FLEXIBLE METAL PIPE
To ensure higher safety, it is recommended to carry out the connection to the gas system using rigid pipes (ex. copper) or using flexible stainless steel pipes, to avoid any stress to the unit.
Gas feeding pipe fitting is Gc 1/2.
For this type of installation, connection to the gas supply should be carried out using only and exclusively flexible metallic tubes in conformity with rules in force.
CONNECTION USING FLEXIBLE,
NON METAL PIPES
When the connection can be easily inspected in its full extent, there is the chance to use a flexible pipe according to the rules in force.
The flexible pipe must be tightly fixed using clamps according to the rules in force.
The flexible pipe should be made ready for use in such a way that:
-nowhere it can reach overtemperature, other than room temperature, higher than 30°C; if the flexible
pipe, to reach the cock, must run behind the range, it must be installed as shown in Fig. 13;
- it is no longer than 1500 mm;
-it shows no throttles;
- it is not subject to traction or torsion;
-it doesn't get in touch with cutting edges or corners;
-it can be easily inspected in order to check its
condition.
The control of preservation of the flexible pipe consists in checking that:
-it doesn't show cracks, cuts, marks of burnings both on the end parts and on its full extent;
-the material is not hardened, but shows its normal elasticity;
- the fastening clamps are not rusted; - expiry term is not due.
If one or more abnormalities are seen, do not repair the pipe, but replace it.
IMPORTANT
FO 0163
Once installation is complete, check the perfect seal of every pipe fitting, using a soapy solution, never a flame.
YES
FLEXIBLE
RUBBER
GAS PIPELINE
ELECTRIC
WIRE
NO
FLEXIBLE
RUBBER
GAS PIPELINE
ELECTRIC
WIRE
Fig. 13
69