Zanussi ZFC 177 C installation manual Defrosting

Page 9

Defrosting

The freezer compartment will become progressively covered with frost. This should be removed with the special plastic scraper provided whenever the thickness of frost exceeds ¼".

During this operation it is not necessary to switch off the power supply or to remove the foodstuffs.

However, when the ice becomes very thick on the inner liner, complete defrosting should be carried out and it is advisable to perform this operation when the appliance is empty.

To carry out complete defrosting:

1.Disconnect the appliance from the electrical supply.

2.Remove any stored food, wrap in several layers of newspaper and store in a cool place.

3.Leave the lid open.

4.Remove the plug from the defrost water drain.

5.To accelerate the defrosting process place a bowl of hot (not boiling) water inside the freezer and close the lid.

6.The defrost water can be collected in a bowl, as shown.

7.When defrosting is completed, dry the interior thoroughly and replace the plug on the defrost water drain.

8.Reconnect the appliance to the electricity supply and leave to run for at least 2 hours on a medium setting.

9.Replace the previously removed food.

Important

A temperature rise of the frozen food packs during defrosting may shorten their safe storage life.

Never use sharp metal tools to scrape off frost from the evaporator as this could damage the appliance beyond repair.

9

Image 9
Contents 820 41 82 ZanussiInstallation Prior to InstallationChild Safety General SafetyContents Description of the Appliance Control PanelGreen light Red light Operation Freezing Fresh Food Frozen Food StorageThawing Baskets Event of a Power Failure Energy Saving AdviceHints & Tips Normal Operating SoundsDefrosting Internal Cleaning Maintenance and CleaningSomething not Working Symptom Check if SolutionCustomer Care Department Service and Spare PartsGuarantee Conditions This Guarantee does not coverGermany Nurenberg +49 Installation Technical SpecificationsClimatic classification Ambient temperature limits HeatElectrical Connection Electrical RequirementsGreen and Yellow Earth BlueNeutral BrownLive Printed by Océ Hungária Kft 2006