INSTALLATION INSTRUCTIONS
WARNINGS
WARNINGS:
This appliance must be installed by a qualified electrician/competent person. Safety may be impaired if installation is not carried out in accordance with these instructions.
This appliance must be earthed.
Do not remove the screws from the earth tab extending from the oven mains terminal block (Fig. 1).
Fig.1
Before connecting the appliance make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This is situated on the front frame of the appliance and can be seen upon opening the door. Alternatively the rating plate may also be found on the back or top of some models (where applicable).
Do not alter the electrical circuitry of this appliance.
CHOICE OF ELECTRICAL CONNECTION
The appliance should be operated using at least 6mm2 twin core and earth PVC insulated multicore cable. Please choose from the most appropriate after reading the descriptions:
By connecting the appliance to a cooker point having a double pole isolating switch providing at least 3mm contact separation in all poles and protected with a fuse or miniature circuit breaker at your mains fuse box.
If you wish to connect an oven and a hob to a cooker point you can, by connecting the oven and hob separately to the cooker point. See Fig. 2.
Fig. 2
7