Instructions for the Installer
Technical data
|
|
|
|
|
|
|
| Model |
|
| TB 110 FF |
| |
|
|
|
|
|
|
|
| Gross capacity (l) |
|
| Freezer: | 105 |
|
|
|
|
| Refrigerator: 195 |
| |
|
|
|
|
|
|
|
| Net capacity (l) |
|
| Freezer: | 80 |
|
|
|
|
| Refrigerator: 192 |
| |
|
|
|
|
|
|
|
| Width (mm) |
|
| 600 |
|
|
|
|
|
|
|
|
|
| Height (mm) |
|
| 1790 |
|
|
|
|
|
|
|
|
|
| Depth (mm) |
|
| 600 |
|
|
| Energy consumption (kWh/24h) |
|
| 1,42 |
|
|
| (kWh/year) |
|
| 518 |
|
|
| Energy class, according to EU standards |
|
| C |
|
|
|
|
|
|
|
|
|
| Freezing capacity (kg/24h) |
|
| 18 |
|
|
|
|
|
|
|
|
|
| Rising time (h) |
|
| 20 |
|
|
|
|
|
|
|
|
|
| Rated power (W) |
|
| 150 |
|
|
|
|
|
|
|
|
|
| Weight (kg) |
|
| 65 |
|
|
|
|
|
|
|
|
|
| Number of compressors |
|
| 1 |
|
|
|
|
|
|
|
|
|
Installing the appliance
Transportation, unpacking
It is recommended to deliver the appliance in original packaging, in vertical position
considering the protective warning on packaging.
After each transportation the appliance must not be switched on for approx. 2 hours.
Unpack the appliance and check if there is any damage. Report possible damage immediately to the retailer.
Location
The appliance should be positioned in a well ventilated, dry room.
Energy use is affected by the ambient temperature. The appliance should therefore:
The following table shows which ambient temperature is correct for each climate classification:
Climate Classification | Ambient Temperature |
SN | +10 to +32 °C |
N | +16 to +32 °C |
ST | +18 to +38 °C |
If installation next to a source of heat is unavoidable, the following minimum clearances must be maintained at the sides of the appliance:
for electric cookers 3 cm
for oil and coal fired ranges 30 cm
not be installed next to radiators, cookers or other sources of heat
only be installed at a location where the ambient temperature corresponds to the climate classification, for which the appliance is designed.
The climate classification can be found on the serial plate.