Tricity Bendix SIE424 installation instructions Introduction, Rating Plate, Installation

Page 8

INTRODUCTION

WARNING: THIS APPLIANCE MUST BE EARTHED

RATING PLATE

This is situated on the front frame of the appliance and can be seen upon opening the door. Alternatively the rating plate may also be found on the back or top of some models (where applicable).

The appliance must be protected by a suitably rated fuse or circuit breaker. The rating of the appliance is given on the rating plate.

Do not remove the rating plate from the appliance as this may invalidate the guarantee.

INSTALLATION

If your appliance has been damaged in transit, contact your supplier immediately. DO NOT attempt to install it.

Your appliance left the factory fully packaged to protect it from damage. If it is delivered without packaging and damage has occurred, the manufacturer cannot accept responsibility. Contact your supplier for advice.

Once the packaging has been removed the appliance should only be moved by hand. DO NOT use a sack barrow or any other aid to lift the appliance as damage may occur.

Connection to the electricity supply must be carried out by a qualified electrician/competent person.

The recommended cross-section area is six square millimetres (6.00mm2).

The electrical connection should be made using a double pole isolating switch (cooker socket) with at least 3mm contact separation in all poles. The cable must have conductors of sufficiently high cross- sectional area to prevent overheating and deterioration.

The cable must be routed away from potentially hot areas marked by X in the diagram below.

To move the appliance, open the main oven door, and lift the appliance by holding inside the top of the compartment.

This is a type Y appliance which means it is free- standing and can be fitted with cabinets on one or both sides. It may also be fitted in a corner setting.

Side walls which are above hob level should be protected by heat resistant non-combustible material and MUST NOT be nearer than 40mm to the hob side.

A nominal air gap of 2mm all around the appliance is required to enable the appliance to be moved into position.

Always ensure an air gap is maintained at hotplate level. Tiles or other forms of deep wall covering should not obscure this gap.

Air gap

Overhanging surfaces or a cooker hood should be a minimum of 685mm above the hob.

It is important to ensure that the appliance is level after installation. Levelling feet are fitted to the appliance to accommodate uneven floors.

8

Image 8
Contents SIE424 Technical Details Model NO. SIEContents Uses of Defrost Feature Selecting Defrost Preface Safety During OperationAfter USE GeneralRating Plate InstallationIntroduction General Notes on Using Your Appliance About Condensation and SteamCooling FAN for Controls Grill and Oven FurnitureFeatures Getting to Know Your ApplianceControl Panel AB C DEElectronic Minute Minder To SET the Time of DAYTo Cancel the Minute Minder Minute MinderHints and Tips Ceramic HOBRecommended Saucepans Special Frying Note Deep FAT FryingPreserving Dual Grill Uses of the GrillSelecting the Grill Things to NoteGrilling Chart Hints and TipsTOP Oven Uses of the TOP OvenSelecting the TOP Oven To FIT the TOP Oven ShelfHints and Tips Main FAN Oven Uses of the FAN OvenSelecting the FAN Oven To FIT the Main Oven ShelvesHints and Tips Oven Cooking Chart Roasting Chart Roasting ChartSelecting Defrost Defrost FeatureUses of Defrost Feature Care and Cleaning Cleaning the Grill and Oven Furniture Cleaning Inside the Oven and Grill CompartmentsTo Remove Burnt on Soilage To Remove Discolourations or White and Silver MarksCare of Stayclean Surfaces Cleaning the Door GlassCleaning Between the Outer and Inner Door Glass To Remove the Outer GlassTo Replace the Outer Glass To Clean the Inner Glass Door PanelsReplacing the Oven Light Bulb Something not WORKING? Appliance does not work at allService and Spare Parts Guarantee Conditions Standard guarantee conditionsPage Consumer care telephone number 08705 Important Notice