Tricity Bendix SG 210 manual Electrical Connections, Permanent Connection

Page 19

ELECTRICAL CONNECTIONS

Any electrical work required to install this cooker should be carried out by a qualified electrician or competent person, in accordance with the current regulations.

THIS COOKER MUST BE EARTHED.

The manufacturer declines any liability should these safety measures not be observed.

This cooker is designed to be connected to a 230-240V AC 50Hz electrical supply.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the cooker rating plate. The rating plate is located on the oven frame.

The cooker is supplied with a 3-core flexible supply cord incorporating a 13amp plug fitted. In the event of having to change the fuse, a 5amp ASTA approved (BS 1362) fuse must be used. Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

-Connect the green and yellow (earth) wire to the terminal in the plug, which is marked with

the letter 'E' or the earth symbol or coloured green and yellow.

-Connect the blue (neutral) wire to the terminal in the plug, which is marked with the letter 'N' or coloured black.

-Connect the brown (live) wire to the terminal in the plug, which is marked with the letter 'L' or coloured red.

NOTE: The earth wire should be about 2 cm longer than the live and neutral wires.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

A cut off plug inserted into a 13-amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safety.

Before connecting check that:

The plug used for connection is easily accessible when the appliance is installed.

Permanent Connection

In the case of a permanent connection, it is necessary that you install a double pole switch between the cooker and the electricity supply (mains), with a minimum gap of 3mm, between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.

The switch must not break the yellow and green earth cable at any point.

Ensure that the cooker supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.

19

Image 19
Contents GAS Cooker Page Contents Important Safety Information Hob Description of the ApplianceBefore the First Use of the Cooker Using the ApplianceGas Mark IgnitionEffects of dishes on cooking results Condensation and steamOven Cooking CookwareGrilling Grill burner ignitionIgnition of the burners Grilling meatBrowning Hob BurnersSelecting the Correct burner Accessories delivered with the applianceExtinguishing of burners Maintenance and Cleaning Burners HobSomething not Working Symptoms SolutionsCustomer Care Service and Spare PartsExclusions Guarantee ConditionsStandard Guarantee Conditions European GuaranteeInstructions for the Installer Gas connections Advice for SafetyConnection to gas supply Permanent Connection Electrical ConnectionsLocation of appliance InstallationRight Hand Connection from front GAS ConnectionsLeft Hand Connection from front Rigid Connection Fixing and use of the 2 clips provided with the cookerConversion of GAS Replace the nozzles of the hob burners Adjustment of minimum level for the hob burnersOven burner Flame adjustment Oven burnerTable no.2 Gas type Air adjusting mm Oven Grill Replace the nozzles of the oven burnersAdjustment of minimum level Page SG210W 342 724 Electrolux plc