Tricity Bendix SG211X manual Advice for safety, Gas connections, Connection to gas supply

Page 20

Advice for safety

Gas connections

Before installation ensures that the local distribution conditions (gas type and pressure) and the pre-setting of the appliance are consistent.

This appliance must be installed only in a room with good ventilation.

This appliance must not connect to a chimney. It has to be installed and connected in accordance with the rules in force. Special attention should be paid to the applicable disposal concerning ventilation.

The adjacent furniture panels have to be heat proof or protected by such material.

The adjusting conditions of this appliance are mentioned on the rating plate.

Connection to gas supply.

Check that the gas flow and the diameter of the supply pipe is sufficient to supply all the appliances of the installation.

Check that all connections are tight.

Install an accessible and visible gas tap to isolate the appliance.

The manufacturer declines any responsibility for possible damages resulting from an installation, which doesn't comply with current legislation.

-Installation of flues and ventilation for gas appliances of rated input not exceeding 60 kW (1st, 2nd and 3rd family gases) – Part 2 Specification for installation of ventilation for gas appliances – BS 5440 Current editions;

-Gas burning appliances – Part 3 Domestic cooking appliances burning gas – BS 5386 Current editions;

20

-Specification for installation of low pressure gas pipe work of up to 20mm (R1) in domestic premises (2nd family gas) – BS 6891 Current editions;

-Pipe threads for tubes and fittings where pressure-tight joints are made on the threads (metric dimensions) – BS 21 Current editions;

-Flexible hoses, end fittings and sockets for gas burning appliances – BS 669 Current editions;

-Installation of domestic gas cooking appliances (1st, 2nd and 3rd family gases)

– BS 6172: 1990 Current editions; For appliances installed in the Republic of Ireland please refer to NSAI-Domestic Gas

Installation IS813 Current editions.

Electrical connections

Any electrical work required to install this cooker should be carried out by a qualified electrician or competent person, in accordance with the current regulations.

THIS COOKER MUST BE EARTHED.

The manufacturer declines any liability should these safety measures not be observed.

This cooker is designed to be connected to a 230-240V AC 50Hz electrical supply.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the cooker rating plate. The rating plate is located on the oven frame.

Image 20
Contents Instruction Book GAS Cooker Contents During Use Important safety informationChild Safety Service Environmental InformationInstructions for the user Control panelGrill function Use of applianceUse During a power cut Gas Mark Temperature oCIgnition Turning off the oven burnerPage Browning Cooking chart\ Enamelled 20 min. for each 0.5 Kg / rareUsing the Hob Hob Burners Or Power CutTurning off the burners Ignition of the burnersDiameter mm Cookware Hints and TipsCondensation and steam Burners Maintenance and cleaningHob Oven door Removing oven door from its hinges Replacing the oven door on its hingesSomething not working 08705 Service and spare partsCustomer care Guarantee conditions Standard Guarantee ConditionsEuropean Guarantee ExclusionsInstructions for the installer Technical features Free standing ClassConnection to gas supply Advice for safetyGas connections Permanent Connection Ventilation InstallationLocation of appliance Gas connections LevellingLeft Hand Connection from front Right Hand Connection from frontPage Conversion of gas Rapid SEMI-RAPID Auxiliary Oven GrillAdjustment of minimum level for the hob burners Grill burner Adjustment of minimum level Oven burnerReplace the nozzles of the oven burners Oven burner Page Page Page Page 342 732 410- 0B Subject to change without notice