Replace the nozzles of the hob burners
Before any modifications or conversion to a kind of different gas, you must DISCONNECT the cooker from the electricity supply and ensure that all control knobs are in the OFF position, and the appliance has cooled completely.
Hob burners
•Remove the pan supports;
•Remove the caps and the burner crowns;
•Using a No 7 socket spanner unscrew the nozzles and replace them with those required for the type of gas in use (see table no. 1).
Reassemble the parts following the same procedure in reverse.
These burners do not need any primary air regulation.
Adjustment of minimum level for the hob burners
The burner is correctly adjusted when the flame is stable silent and goes out without any noise. When changing the type of gas check that the minimum level is correct. The air admission is correct when the flame is about 4 mm in length.
26
The top burners do not need adjustment of primary air.
Check that, turning the knob quickly from the maximum position to the minimum one, the flame does not go out.
no air | correct | excess of |
adjustment | air |
Hob burners
To adjust the minimum level:
•Light the burner
•Turn the knob to the position of the minimum flame;
•Remove the knob;
•Unscrew or screw the
•For LPG screw completely the
Reassemble the parts following the same procedure in reverse.
Check that, when turning the knob quickly from the maximum position to the minimum one, the flame does not go out.