Instructions for the Installer
Instructions for the Installer
Engineers technical data
Overall dimensions
Width: | 880 mm. |
Depth: | 510 mm. |
Cut out dimensions
Width: | 830 mm. |
Depth: | 480 mm. |
Burner | Dia. Tap |
| 1/100 mm |
Auxiliary | 28 |
32 | |
56 |
Aeration adjustment none
Supply Connections
Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
Ignition HT Spark
Spark Generator: Ispra Control's BF 50066 -
Spark Gap : Fixed
Heat Input |
|
3.8 kW Natural Gas | |
(Triple crown) | (12,966 BTU/HR) |
| 3.8 kW L.P.G. |
| (12,966 BTU/HR) |
Auxiliary Burner | 1.0 kW (3,412 BTU/HR) | |
Appliance class |
| 3 |
Appliance category | II2H3+ | |
Gas supply | Natural gas G20 / 20mbar |
| BURNER | AUXILIARY | ||||||
TYPE OF GAS |
| (triple | crown) | (medium) | (small) | |||
|
|
|
|
|
|
| ||
| POSITION | M A X | MIN | M A X | MIN | M A X | MIN | |
NATURAL GAS | NOMINAL THERMAL |
|
|
|
|
|
| |
POWER (kW) | 3.8 | 1.20 | 1.9 | 0.45 | 1.0 | 0.33 | ||
20 mbar | NOMINAL FLOW |
|
|
|
|
|
| |
VALUE = |
|
|
|
|
|
| ||
RATE (m3/h) | 0.362 | 0.114 | 0.181 | 0.043 | 0.095 | 0.028 | ||
37.78 MJ/m3 | ||||||||
Ws - 50.7 MJ/ m3 | NOZZLE REFERENCE | 146 | Adjust. | 96 | Adjust. | 70 | Adjust. | |
| (1/100 mm) |
|
|
|
|
|
| |
LPG GAS | NOMINAL THERMAL |
|
|
|
|
|
| |
POWER (kW) | 3.8 | 1.20 | 1.9 | 0.45 | 1.0 | 0.33 | ||
NOMINAL FLOW |
|
|
|
|
|
| ||
VALUE = |
|
|
|
|
|
| ||
RATE (g/h) | 274 | 86 | 137 | 32.4 | 72 | 23.8 | ||
49.92 MJ/Kg | ||||||||
| NOZZLE REFERENCE | 98 | 40 | 71 | 32 | 50 | 28 | |
| (1/100 mm) |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
11