Sonance installation manual Installing the BPS-1 Cabinet In New Construction, P O Rta N T T H E

Page 2

Architectural Series

BPS - 1 I N - C E I L I N G S U B W O O F E R

I N S T A L L A T I O N M A N U A L

Installing the BPS-1 Cabinet In New Construction

WARNING

DO NOT ATTACH THE BPS - 1 TO AN I - JOIST THAT HAS NOT BEEN ADEQUATELY BRACED . DOING SO CAN CAUSE COLLAPSE, RESULTING IN INJURY OR DEATH . CONSULT WITH THE JOB’S GENERAL CONTRACTOR BEFORE ATTACHING THE BPS - 1 TO AN I - JOIST.

1. Determine the location for the

Architectural Series Panel Bracket/Grille and install it according to its instruction manual.

2. Determine the location for the BPS-1 cabinet.

I M P O RTA N T : T H E

C E N T E R

O F

PA N E L B R A C K E T S S P E A K E R O P E N -

I N G S H O U L D B E A P P R O X I M A T E L Y

12” F R O M V E N T T U B E E N D O F BPS-1

E N C L O S U R E ( S E E

F I G U R E

2 ) .

M A I N T A I N I N G T H E V E N T T U B E S

Panel Bracket

Joists

BPS-1 Cabinet

 

 

 

 

 

 

 

 

 

SonanceArchitectural Series

 

WWW.SONANCE.COM 800.582.7777

 

 

 

 

 

 

 

 

 

 

 

 

B6R

 

 

 

5/8” DRYWALL

 

 

 

 

 

 

 

 

 

 

 

 

12”

P R O P E R L E N G T H I S I N T E G R A L T O T H E

BPS - 1’ S A C O U S T I C

P E R F O R M A N C E .

L E N G T H E N I N G O R

S H O R T E N I N G

T H E V E N T T U B E T O F I T A D I F F E R E N T D I S TA N C E W I L L A D V E R S E L Y A F F E C T T H E

Figure 2: Positioning the BPS-1 Relative to the Panel Bracket

(Note: Vent tube not shown for clarity)

BPS - 1’ S P E R F O R M A N C E .

2. Attach the included Mounting Hole Drilling Template to the ceiling joist at the BPS-1 mounting location (see Figure 3). Make sure that the template is placed high enough so the BPS-1 cabinet will not contact the ceiling material after installation. (Contact can cause buzzing during operation.)

3. Drill eight 5/16" holes through the joist at the locations indicated on the Drilling Template (see Figure 3).

4. Screw the two Temporary Installation Brackets across the underside of the joist bay at the locations indicated on the Drilling Template (see Figure 4). The Temporary Brackets have two sets of pre-drilled holes: One for 24” center-to-center joist spacing, and another for 16” center-to-center joist spacing.

Drilling

Drill Holes for

Template

 

5/16” Lag Screws

Figure 3: Drilling Holes For the Lag Screws

Joists

Temporary

Brackets

Figure 4: Attaching the Temporary Brackets

to the Joists (16” spacing shown)

Page 2 of 8

Image 2
Contents Introduction Design and FeaturesBox Contents Installing the BPS-1 Cabinet In New Construction P O RTA N T T H ESelecting the Proper Adaptor Baffle Connecting the Vent Tube and Adaptor Baffle Remove Panel BracketSpeaker Connections Very ImportantInstalling the Architectural Finish Component BPS-1 Connection TerminalsInstalling the Woofer Cabinet Retrofit SpecificationsW . s o n a n c e . c o m