Safety Instructions
Installation of the range.
Read these instructions completely and carefully.
Three-Wire Cord Connection
Installation Instructions Care and Cleaning Operating Instructions
| Junction block |
Black | on range back |
| |
| Red |
Top nut |
|
Ground |
|
strap | White lead |
Black lead |
|
| Red lead |
| Strain relief |
| clamp |
Remove the top nuts on the junction block studs.
Tighten the back nuts.
Install the three wire cord and the strain relief in the hole in the strain relief bracket.
Connect the red and black leads to the outer terminals and the white lead to the center terminal.
Push the cord upward (to relieve strain), while tightening the strain relief clamp.
If local codes require an ungrounded neutral:
Follow steps 1 through 5.
Junction block
on range back
Black
| Red |
Top nut | Ground wire |
Ground |
|
strap | White lead |
Black lead |
|
| Red lead |
| Strain relief |
| clamp |
Then loosen the screw from the ground strap and fasten a #10 copper wire to the range. Secure the other end of the wire to a grounded cold water pipe or use another approved grounding method.
Four-Wire Cord Connection
Customer Service Troubleshooting Tips
Red
Black
| Ground strap |
Black lead | removed |
| |
Ground | Green lead |
screw |
|
White lead | Red lead |
|
Remove the top nuts on the junction block studs.
Tighten the back nuts.
Remove the ground screw; then remove the ground strap.
Install the four wire cord and strain relief in the hole in the strain relief bracket.
Connect the red and black leads to the outside terminals and the white lead to the center terminal.
Attach the green lead below the junction block with the ground screw that was removed earlier (step 3).
Push the strain relief upward (to relieve strain) while tightening the strain relief clamp.
16