Maytag W10289536A Electrical Connection U.S.A. Only, Power Supply Cord, Direct Wire

Page 8

Electrical Connection - U.S.A. Only

Power Supply Cord

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death, fire, or electrical shock.

Direct Wire

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

1.Disconnect power.

2.Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range. Pull cover down and toward you to remove cover.

4.Add strain relief.

Style 1: Power supply cord strain relief

Assemble a UL listed strain relief in the opening.

A

3. Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block.

A. UL listed strain relief

Feed the power supply cord through the strain relief in the

cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

Tighten strain relief screw against the power supply cord.

8

Image 8 Contents
Range Safety Freestanding Electric Range with Double OvensLocation Requirements Installation RequirementsTools and Parts Product Dimensions Cabinet Dimensions If connecting to a 4-wire system If connecting to a 3-wire system Electrical Requirements U.S.A. Only Electrical ConnectionElectrical Requirements Canada Only Installation Instructions Unpack RangeWall Mounting Install Anti-Tip BracketFloor Mounting Power Supply Cord Direct WireStyle 1 Power supply cord strain relief Electrical Connection U.S.A. OnlyStyle 2 Direct wire strain relief Removable retaining nut Strain reliefWire connection Power Supply Cord Direct Wire Installation Copper or Aluminum Wire Wire Connection Direct WireBare Wire Torque Specifications Wire Awg TorqueComplete Installation Verify Anti-Tip Bracket LocationLevel Range If range does not operate, check the followingMoving the Range For power supply cord-connected rangesFor direct-wired ranges Page Sécurité DE LA Cuisinière Votre sécurité et celle des autres est très importanteOutils et pièces Exigences D’INSTALLATIONExigences d’emplacement Dimensions du product Dimensions du placard Largeur de louverture 30 76,2 cm minSpécifications électriques Canada seulement Réglage des pieds de nivellement Instructions DinstallationDéballage de la cuisinière Montage au mur Installation de la bride antibasculementMontage au plancher Vérification de lemplacement de la bride Antibasculement Achever l’installationRéglage de laplomb de la cuisinière Si la cuisinière ne fonctionne pas, contrôler ce qui suitDéplacement de la cuisinière W10289536A