![](/images/new-backgrounds/1090846/9084625x1.webp)
Follow the instructions below to change the broiler burner nozzle:
1)Loosen the screw and pull out the burner from the support being careful not to damage the ignition plug and the thermocouple (Fig. 11).
2)Unscrew the nozzle C (Fig. 11) using a 7 mm spanner and replace it with the nozzle needed for the new type of gas according to what is indicated in TABLE shown below.
Fig. 11
Models X486GGGVX | [MTYKQZU4(X,L,I,N,R,U,V,W,D)(2 or 5)A] | ||||||||
Adapting to different types of gas |
|
|
|
|
|
| |||
Burner | Position | Injector | Gas | Pressure | Max Rate | Min Rate | |||
|
| diam. [mm.] | Type | [i.w.c.] | [BTU/h] | [W] | [BTU/h] | [W] | diam. [mm] |
Auxiliary | Front R | 0,90 | NG | 4” | 3400 | 996 | 900 | 264 | Regulated |
|
| 0,54 | LP (Propane) | 11” | 3400 | 996 | 900 | 264 | 0,29 |
Rear L & C | 1,18 | NG | 4” | 6100 | 1787 | 1500 | 439 | Regulated | |
| Front C | 0,70 | LP (Propane) | 11” | 6100 | 1787 | 1500 | 439 | 0,36 |
Rapid | Rear R | 1,55 | NG | 4” | 10400 | 3047 | 2500 | 732 | Regulated |
|
| 0,92 | LP (Propane) | 11” | 10400 | 3047 | 2500 | 732 | 0,47 |
Dual Burner | Front L Inner | 0,80 | NG | 4” | 2800 | 820 | 900 | 264 | Regulated |
| 0,49 | LP (Propane) | 11” | 2800 | 820 | 900 | 264 | 0,29 | |
| Front L Outer | N°2 x 1,15 | NG | 4” | 12000 | 3516 | 4500 | 1318 | Regulated |
|
| N°2 x 0,70 | LP (Propane) | 11” | 12000 | 3516 | 4500 | 1318 | 0,65 |
Oven | Oven Left | 1,85 | NG | 4” | 14500 | 4248 | 3500 | 1025 | Regulated |
(left cavity) | downside | 1,10 | LP (Propane) | 11” | 14500 | 4248 | 3500 | 1025 | 0,54 |
Broiler | Oven Left | 1,70 | NG | 4” | 12000 | 3516 | Only Max | Only Max | No |
(left cavity) | upside | 0,98 | LP (Propane) | 11” | 12000 | 3516 | Only Max | Only Max | No |
Oven | Oven Right | 1,25 | NG | 4” | 7000 | 2051 | 2400 | 703 | Regulated |
(right cavity) | downside | 0,75 | LP (Propane) | 11” | 7000 | 2051 | 2400 | 703 | 0,48 |
CAUTION: save the orifices removed from the appliance for future use
REGULATION OF BURNERS
Primary air adjustment:
Broiler burner adjustment: to adjust the broiler burner loosen screw P and adjust the position X of the Venturi cone according to the measurements indicated in table 4.
13