Bertazzoni X486GGGVX dimensions Service & Maintenance Instructions

Page 14

TABLE N°4: Burner primary air regulation (indicative)

 

 

Burner

Type of gas

Broiler

 

 

Inches (mm)

NG

(Natural Gas)

fully open

LP

(Propane Gas)

fully open

Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:

1)Light the burner and set the knob to the MINIMUM position (small flame).

2)Remove the knob of the valve that is press fit on the rod of that valve.

3)The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body and turn the choke screw to the right or left until the burner flame is adjusted to minimum

4)Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.

Oven burner adjustment: follow the instructions below to adjust the minimum:

1)Light the burner setting the knob to the MAXIMUM position.

2)Close the oven door and operate the oven for at least 10 minutes.

3)Set the knob to the MINIMUM position (corresponding to 250°F/120°C) and then remove it.

4)With a slotted screwdriver turn the choking screw (by-pass screw at the left side of the thermostat bar) and, while observing the flame at the same time through the cooker porthole, evaluate the consistency of the flame so it remains on when switching quickly from the MINIMUM to the MAXIMUM position.

WARNING: The above-mentioned adjustment should be made only for natural gas, while for operation with liquid gas the screw must be locked at the end in a clockwise direction. The broiler burner always operates at maximum and therefore no minimum adjustment is required.

SERVICE & MAINTENANCE INSTRUCTIONS

Service and maintenance only to be carried out by an authorised person

To replace parts such as burners, valves and electric components, the appliance must be open removing the worktop. Note: if the valves must be replaced, first disassemble the ignitions switches wires.

It is recommended to replace the valve gaskets each time the valve is replaced, thus ensuring a perfect seal between the body and the gas train.

WARNING: After first installation of the appliance or after any service intervention concerning main gas parts of the appliance, make the leak test using water with soap on the gas connections in order to verify the correct installation. Do not use fire for gas leak testing.

To replace the oven bulb, just unscrew the protection cap that projects out inside the oven. (Fig.19) WARNING:

Disconnect power before servicing unit.

In order to remove the oven door make sure to block the ihinges with a screw driver.

Call an autorised service person for this operation that can be dangerous

14

Image 14
Contents Bertazzoni What to do if YOU Smell GAS Installation instructions Installation Manual Backguard Installation Instruction Height adjustable legsWorktop Frontguard Installation Instructions Installation SIDE-BY-SIDE to Kitchen Cabinet Cooker Hood Installation Electrical ConnectionGAS Connection Manual Shut-off ValvePerformance CHECKLlST Replacement Parts Final PreparationChanging the Nozzles for USE with Other Types of GAS Models X486GGGVX Regulation of BurnersService & Maintenance Instructions Important Instruction Descriptions Control Panel DescriptionUsing Burners Manual ignitionUsing the Electric Griddle Using the Left GAS Oven Table N7Fish Using the GAS Broiler only left oven Using the Right GAS Oven Table N8Cleaning the Appliance After Sale Service Spare Part List Oven Convection FAN Small Blue BUD Page Page Page Page Page Page Page