Bertazzoni X365GGVBI, X365GGVGI, X365GGVCR manual Models X366GGVX X36 6 00 X M3Y0GTU4X2 or 5A

Page 20

Models X366GGVX (X36 6 00 X) [M3Y0GTU4X(2 or 5)A]

Burner

Position

Injector

Gas

Pressure

Max Rate

Min Rate

By‐pass

 

 

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

diam. [mm]

Auxiliary

Front R

0,90

NG

4”

3400

996

900

264

Regulated

 

 

0,54

LP (Propane)

11”

3400

996

900

264

0,29

Semi‐Rapid

Rear L & C

1,18

NG

4”

6100

1787

1500

439

Regulated

 

Front C

0,70

LP (Propane)

11”

6100

1787

1500

439

0,36

Rapid

Rear R

1,55

NG

4”

10400

3047

2500

732

Regulated

 

 

0,92

LP (Propane)

11”

10400

3047

2500

732

0,47

 

Front L Inner

0,80

NG

4”

2800

820

900

264

Regulated

Dual Burner

 

0,49

LP (Propane)

11”

2800

820

900

264

0,29

 

Front L Outer

N°2 x 1,15

NG

4”

12000

3516

4500

1318

Regulated

 

 

N°2 x 0,70

LP (Propane)

11”

12000

3516

4500

1318

0,65

Oven

Oven

2,00

NG

4”

16000

4688

4000

1172

Regulated

 

downside

1,15

LP (Propane)

11”

16000

4688

4000

1172

0,60

Broiler

Oven

1,90

NG

4”

14500

4248

Only Max

Only Max

No by‐pass

 

upside

1,10

LP (Propane)

11”

14500

4248

Only Max

Only Max

No by‐pass

Models X365GGVX (X36 5 00 X) [M3W0GTU4X(2 or 5)A]

Burner

Position

Injector

Gas

Pressure

Max Rate

Min Rate

By‐pass

 

 

diam. [mm.]

Type

[i.w.c.]

[BTU/h]

[W]

[BTU/h]

[W]

diam. [mm]

Auxiliary

Front R

0,90

NG

4”

3400

996

900

264

Regulated

 

 

0,54

LP (Propane)

11”

3400

996

900

264

0,29

Semi‐Rapid

Rear L and R

1,18

NG

4”

6100

1787

1500

439

Regulated

 

 

0,70

LP (Propane)

11”

6100

1787

1500

439

0,36

Rapid

Front L

1,55

NG

4”

10400

3047

2500

732

Regulated

 

 

0,92

LP (Propane)

11”

10400

3047

2500

732

0,47

 

Centre Inner

0,80

NG

4”

2800

820

900

264

Regulated

Dual Burner

 

0,49

LP (Propane)

11”

2800

820

900

264

0,29

 

Centre Outer

N°2 x 1,15

NG

4”

12000

3516

4500

1318

Regulated

 

 

N°2 x 0,70

LP (Propane)

11”

12000

3516

4500

1318

0,65

Oven

Oven

2,00

NG

4”

16000

4688

4000

1172

Regulated

 

downside

1,15

LP (Propane)

11”

16000

4688

4000

1172

0,60

Broiler

Oven

1,90

NG

4”

14500

4248

Only Max

Only Max

No by‐pass

 

upside

1,10

LP (Propane)

11”

14500

4248

Only Max

Only Max

No by‐pass

20

Image 20
Contents INSTALLATION, USE & Care Manual Freestanding GAS Ranges From the desk of the President Table of Contents Replacement Parts Warranty and ServiceCustomer Service Important Safety Information What to do if YOU Smell GASProduct Specifications Auxiliary 3400 BTU/hBefore Installation Type of GASInstalling the Legs Installing the Worktop FrontguardInstalling the Backguard GAS DeviceElectrical Installation Adjacent to Kitchen Cabinets Exhaust Hood InstallationWiring Diagram Electrical ConnectionElectrical Grounding Electrical Shock HazardDo not USE AN Open Flame When Checking For Leaks GAS ConnectionManual SHUT‐OFF Valve Flexible ConnectionsPressure Regulator GAS Conversion Surface Burners Main Oven BurnerBroiler Burner Visual Checks Connection of Thermocouples to ThermostatMinimum Flame Adjustment Oven BurnerModels X366GGVX X36 6 00 X M3Y0GTU4X2 or 5A Installation CHECKLlST Final PreparationRoom Ventilation Surface Burner LayoutSurface Burner Operation SymbolsSurface Cooking Tips for Using Pans Correctly Oven Cooking Oven ShelvesGAS Oven Operation Thermocouple Safety Valve Electric IgnitionConvection Cooking Cooking with the GAS BroilerCleaning Your Range Maintaining Your RangeReplacing the Oven Light Bulb Cooling FAN FailureImportant Appliance Information Italy Spare Part List Side RED Page Page Page Page Page