Bertazzoni X365GGVGI, X365GGVCR, X365GGVBI manual GAS Conversion

Page 15

GAS CONVERSION

WARNING!

Before carrying out this operation, disconnect

the appliance from gas and electricity.

Gas conversion shall be conducted by a factory‐

trained professional.

Call the customer service hotline to identify a factory‐trained professional near your home.

The gas conversion procedure for this range includes 6 steps:

1.Pressure regulator

2.Surface burners

3.Main oven burner

4.Broiler burner

5.Visual checks prior to closure of oven bottom panel

6.Adjustment of minimum setting

The conversion is not completed if all 6 steps have not been concluded properly.

Before performing the gas conversion, locate the package containing the replacement nozzle shipped with every range. IMPORTANT: Each nozzle has a number indicating its flow diameter printed on the body. Consult the table on page 20 for matching nozzles to burners.

Save the nozzles removed from the range for future use.

STEP 1: PRESSURE REGULATOR

The pressure regulator supplied with the appliance is a convertible type pressure regulator for use with Natural Gas at a nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet pressure of 11” w.c. and it is pre‐arranged from the factory to operate with one of these gas/pressure as indicated in the labels affixed on the appliance, package and Instruction booklet.

To convert the regulator for use with other liquid propane LP gas:

1.Unscrew by hand the upper cap of the regulator, remove the white plastic attachment from the cap, reverse its direction and screw it again firmly against the cap. The white plastic attachment has arrows indicating the position for natural gas (NAT) and LP gas (LP).

2.Screw by hand the metal cap in the original position on the regulator.

15

Image 15
Contents INSTALLATION, USE & Care Manual Freestanding GAS Ranges From the desk of the President Table of Contents Warranty and Service Customer ServiceReplacement Parts What to do if YOU Smell GAS Important Safety InformationAuxiliary 3400 BTU/h Product SpecificationsType of GAS Before InstallationInstalling the Worktop Frontguard Installing the LegsInstalling the Backguard Device ElectricalGAS Exhaust Hood Installation Installation Adjacent to Kitchen CabinetsElectrical Shock Hazard Wiring DiagramElectrical Connection Electrical GroundingFlexible Connections Do not USE AN Open Flame When Checking For LeaksGAS Connection Manual SHUT‐OFF ValvePressure Regulator GAS Conversion Main Oven Burner Surface BurnersBroiler Burner Connection of Thermocouples to Thermostat Visual ChecksOven Burner Minimum Flame AdjustmentModels X366GGVX X36 6 00 X M3Y0GTU4X2 or 5A Final Preparation Installation CHECKLlSTSurface Burner Layout Room VentilationSymbols Surface CookingSurface Burner Operation Tips for Using Pans Correctly Oven Shelves Oven CookingElectric Ignition GAS Oven Operation Thermocouple Safety ValveCooking with the GAS Broiler Convection CookingCooling FAN Failure Cleaning Your RangeMaintaining Your Range Replacing the Oven Light BulbImportant Appliance Information Italy Spare Part List Side RED Page Page Page Page Page