Parkinson Cowan CSIM 509 manual Commissioning

Page 22

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

-Turn the gas tap to the MAX position and ignite.

-Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

ΦRe-ignite the burner and set to MIN. Remove the control knob.

The adjustment screw is located down the centre of the gas tap control shaft or on the lower right hand side of the shaft (see diagram).

To adjust, use a thin bladed screwdriver and turn the adjustment screw until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for all burners.

Pressure Testing

ΦRemovecap and crown.left hand pan support and front left burner Fit manometer tube over the injector.

Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar. Turn off the burner supplies.

a

FO 1032

a)Minimum adjustment screw

b)Tap

22

Image 22
Contents Csim Important Safety Information Contents Description of the CookerControl Panel AccessoriesOven Cavity Hob burners Using the HobTriple-crown burner Before the First Use of the Cooker Electric OvenUsing the Oven Hints and TipsHints and Tips ΦHow to Use the Fan OvenΦHow to Use Defrosting Things to NoteFan Cooking Chart Defrosting ChartΦHow to Use the Grill GrillingMaintenance and Cleaning Cleaning the OvenOven Cavity Oven lamp replacementOven Shelves Symptom Solution Something Not WorkingParkinson Cowan Standard Guarantee conditions Service and Spare PartsGuarantee Conditions Customer CareNorthernireland Midlands Dimensions Instructions for the InstallerTechnical Data HobLocation Important Safety RequirementsProvision for Ventilation Positioning the CookerSplash back Assembly InstallationFeet Assembly Positioning the Appliance FigConnecting to Gas Fitting the Stability Bracket Not suppliedPermanent Connection Electrical connectionsThis Cooker Must be Earthed Commissioning To Adjust the GAS Rate Conversion from Natural to LPG GasCustomer Care