Important Safety Requirements

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations (current addition) and the I.E.E. Wiring Regulations. Detailed recommendations are contained in the following British Standard Codes of Practice - B.S. 6172, B.S. 5440: Part 2 and B.S. 6891: Current Editions.

Provision for Ventilation

The room containing the cooker should have an air supply in accordance with B.S. 5440: Part 2: Current Editions. The following requirements for ventilation must be met. The cooker should not be installed in a bed sitting room with a volume of less than 20m3, if it is installed in a room of volume less 5m3 an air vent of effective area of 110cm2 is required; if it is installed in a room of volume between 5m3 and 10m3, an air vent of effective area 50cm2 is required, while if the volume exceeds 11m3 no air vent is required. However, if the room has a door which opens directly to the outside, no air vent is required even when the volume is between 5m3 and 11m3.

If there are other fuel burning appliances in the same room, B.S. 5440: Part. 2: Current Editions should be consulted to determine the requisite air vent requirements.

Location

The cooker may be located in a kitchen, a kitchen/diner or bedsitting room but not in a bathroom, shower room or garage.

For information regarding the fitting of flexible supply pipes, the highest temperature at the rear of this cooker which may come into contact with the supply pipe is 70°C above ambient.

When the appliance has been installed there must be enough space fot the hotplate lid (when present) to open fully.

Positioning the Cooker

Caution:

Some soft or badly fitted floor coverings can be damaged when the cooker is moved across their surface for cleaning. It is advisable to ensure that the floor covering in the area below the cooker is either securely fixed so as not to ruck up when the cooker is moved or, if preferred, removed.

18

Image 18
Contents Csim Important Safety Information Contents Description of the CookerAccessories Control PanelOven Cavity Using the Hob Hob burnersTriple-crown burner Before the First Use of the Cooker Electric OvenUsing the Oven Hints and TipsHints and Tips ΦHow to Use the Fan OvenΦHow to Use Defrosting Things to NoteFan Cooking Chart Defrosting ChartΦHow to Use the Grill GrillingMaintenance and Cleaning Cleaning the OvenOven lamp replacement Oven CavityOven Shelves Symptom Solution Something Not WorkingParkinson Cowan Standard Guarantee conditions Service and Spare PartsGuarantee Conditions Customer CareNorthernireland Midlands Dimensions Instructions for the InstallerTechnical Data HobLocation Important Safety RequirementsProvision for Ventilation Positioning the CookerSplash back Assembly InstallationFeet Assembly Positioning the Appliance FigConnecting to Gas Fitting the Stability Bracket Not suppliedElectrical connections Permanent ConnectionThis Cooker Must be Earthed Commissioning To Adjust the GAS Rate Conversion from Natural to LPG GasCustomer Care