MAINTENANCE
CAUTION
Inspection and other services should always be carried out on hard and level ground with the engine shutdown.
Inspection and Maintenance ServiceTables.
1.To make sure your plate compactor is always in good working condition before using, carry out the maintenance inspection in accordance with Tables 5 through 7.
CAUTION
These inspection intervals are for operation under normal conditions. Adjust your inspection intervals based on the number hours plate compactor is in use, and particular working conditions.
CAUTION
Fuel piping and connections should be replaced every 2 years.
Table 5. Engine Maintenance Schedule
|
|
| FIRST |
| EVERY | EVERY | EVERY | EVERY |
DESCRIPTION (3) | OPERATION | BEFORE | MONTH |
| 3 MONTHS | 6 MONTHS | YEAR | 2 YEARS |
OR |
| OR | OR | OR | OR | |||
|
|
|
| |||||
|
|
| 10 HRS. |
| 25 HRS. | 50 HRS. | 100 HRS. | 200 HRS. |
|
|
|
|
|
|
|
|
|
Engine Oil | CHECK | X |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
CHANGE |
| X |
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
Air Cleaner | CHECK | X |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
CHANGE |
|
|
| X (1) |
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
All Nuts & Bolts | X |
|
|
|
|
|
| |
Necessary |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
Spark Plug |
|
|
|
| X |
|
| |
|
|
|
|
|
|
|
| |
REPLACE |
|
|
|
|
|
| X | |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
Cooling Fins | CHECK |
|
|
|
| X |
|
|
|
|
|
|
|
|
|
|
|
Spark Arrester | CLEAN |
|
|
|
|
| X |
|
|
|
|
|
|
|
|
|
|
Fuel Tank | CLEAN |
|
|
|
|
| X |
|
|
|
|
|
|
|
|
|
|
Fuel Filter | CHECK |
|
|
|
|
| X |
|
|
|
|
|
|
|
|
|
|
Idle Speed |
|
|
|
|
| X (2) |
| |
|
|
|
|
|
|
|
|
|
Valve Clearance |
|
|
|
|
|
| X (2) | |
|
|
|
|
|
|
|
|
|
Fuel lines | CHECK |
|
| Every 2 years (replace if necessary) (2) |
| |||
|
|
|
|
|
|
|
|
|
(1)Service more frequently when used in DUSTY areas.
(2)These items should be serviced by your service dealer, unless you have the proper tools and are mechanically proficient. Refer to the HONDA Shop Manual for service procedures.
(3)For commercial use, log hours of operation to determine proper maintenance intervals.
PAGE 20 — MVC80VH/VHW PLATE COMPACTOR — OPERATION AND PARTS MANUAL — REV. #3 (1/13/11)