Sharp R-22AT, R-24AT service manual Test Procedures, Procedure Letter Component Test Magnetron Test

Page 11

R-22AT

R-24AT

 

TEST PROCEDURES

PROCEDURE

 

LETTER

COMPONENT TEST

AMAGNETRON TEST

NEVER TOUCH ANY PART IN THE CIRCUIT WITH YOUR HAND OR AN INSULATED TOOL WHILE THE OVEN IS IN OPERATION.

CARRY OUT 3D CHECKS.

Isolate the magnetron from high voltage circuit by removing all leads connected to filament terminal.

To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the meter should show a reading of less than 1 ohm.

To test for short circuit filament to anode condition, connect ohmmeter between one of the filament terminals and the case of the magnetron (ground). This test should be indicated an infinite resistance. If a low or zero resistance reading is obtained then the magnetron should be replaced.

MICROWAVE OUTPUT POWER (1 litre water load)

The following test procedure should be carried out with the microwave oven in a fully assembled condition (outer case fitted). Microwave output power from the magnetron can be measured by way of IEC 60705, i.e. it is measured by how much power the water load can absorb. To measure the microwave output power in the microwave oven, the relation of calorie and watt is used. When P(W) heating works for t(second), approximately P x t/4.187 calorie is generated. On the other hand, if the temperature of the water with V(ml) rises T (°C) during this microwave heating period, the calorie of the water is V x T.

The formula is as follows;

 

 

 

 

 

P x t / 4.187 = V x T+ 0.55 x mc (T2-T0)

P (W) = 4.187 x V x T / t + 0.55 x mc (T2-T0)/t

Our condition for water load is as follows:

 

 

 

Room temperature (T0)

......

around 20°C

Power supply Voltage

Rated voltage

Water load

1000 g

Initial temperature (T1)

10±1°C

Heating time

28 sec. [R-22AT] / 22sec. [R-24AT] Mass of container (mc)

..... 330 g

T2

Final Temperature

P = 150 x T [R-22AT] / P = 190 x T [R-24AT]

 

 

 

 

 

 

 

 

Measuring condition:

1.Container

The water container must be a cylindrical borosilicate glass vessel having a maximum material thickness of 3 mm and an outside diameter of approximately 190 mm.

2.Temperature of the oven and vessel

The oven and the empty vessel are at ambient temperature prior to the start the test.

3.Temperature of the water

The initial temperature of the water is (10±1)°C.

4.Select the initial and final water temperature so that the maximum difference between the final water temperature and the ambient temperature is 5°C.

5.Select stirring devices and measuring instruments in order to minimize addition or removal of heat.

6.The graduation of the thermometer must be scaled by 0.1°C at minimum and be an accurate thermometer.

7.The water load must be (1000±5) g.

8.“t” is measured while the microwave generator is operating at full power. Magnetron filament heat- up time is not included.

NOTE: The operation time of the microwave oven is “t + 3” sec. (3 sec. is magnetron filament heat-up time.)

Measuring method:

1.Measure the initial temperature of the water before the water is added to the vessel. (Example: The initial temperature T1 = 11°C)

2.Add the 1 litre water to the vessel.

3.Place the load on the centre of the shelf.

4.Operate the microwave oven at HIGH until the temperature of the water rises by a value T of (10 ± 2) K.

5.Stir the water to equalize temperature throughout the vessel.

6.Measure the final water temperature. (Example: The final temperature T2 = 21°C)

7.Calculate the microwave power output P in watts from above formula.

9

Image 11
Contents Commercial Microwave Oven Table of ContentsRemember to Check 4R Remember to Check 3DGeneral Important Information Sharp Corporation OSAKA, JapanCommercial Microwave Oven 22AT/ R-24ATBrown Live SpecificationDescription This Appliance Must be EarthedAuto Touch Control Panel Installation InformationDisplay and Indicators Appearance ViewMicrowave Variable Cooking Operation SequenceIdle Condition Microwave Cooking ConditionFigure B-1. High Voltage Circuit TWO Magnetron Operation SystemFunction of Important Components Troubleshooting Guide EEP ROM KEY Unit Touch Control Transformer T3 Possible Cause and Defective PartsMicrowave Output Power 1 litre water load Test ProceduresProcedure Letter Component Test Magnetron Test Microwave Output Power 2000 cc alternative method Test Procedures Letter Component TestPower Carry OUT 4R Checks High Voltage Rectifier Assembly Test Carry OUT 3D ChecksSwitch Test Carry OUT 4R ChecksFuse F1, F2 F10A Test Carry OUT 3D Checks Procedure Letter Component TestTemperature Fuse TF1, TF2, TF3 Test Weak Point F3 Test Carry OUT 3D ChecksHigh Voltage Fuse F4, F5 Test Carry OUT 3D Checks Touch Control Panel Assembly TestMotor Winding Test Noise Filter TestRY3 KEY Unit TestRelay Test RY1Occurrence Cause or Correction Touch Control Panel Assembly LSIIXA222DR Description of LSIPower source voltage Signal to sound buzzerSignal synchronized with commercial power source frequency Internal clock oscillation frequency setting inputSound Voltage level control terminal Digit selection signalKey strobe signal Servicing of Touch Control Panel ServicingShapes of Electronic Components PAD Order Display Phone Other PrecautionsServicing Tools Defrost Procedure for Entering toOther Checking and Clearing PROCE- Dure for Employing lead-free solder Precautions for Using LEAD-FREE SolderSET Number Double Quantity Check Signal Using lead-free wire solderHigh Voltage Transformers Removal Component Replacement and Adjustment ProcedureOuter CASE, Rear Cabinet and Power Supply Cord Removal Removal Magnetron Thermistor ReplacementRe-install Magnetrons RemovalStirrer Motors Upper and Lower Removal HOW to Release the Positive Lock ConnectorTerminal Insulator Replacement Blower Motor RemovalHOW to Attach Membrane Switch and Graphic Sheet Control Panel Assembly and Control Unit RemovalPower Supply Cord Replacement Control Panel Assembly RemovalRemoval Door Replacement and AdjustmentAfter adjustment, make sure of the following Door Components Removal Door DisassemblyChoke Cover Removal Door Glass Removal Service InformationUpper and Lower Latch Heads Removal Door Case RemovalPreparation ProcedureMicrowave Measurement Figure O-1 Oven Schematic-OFF Condition Figure O-3 Oven Schematic-Cooking Condition Figure S-1. Pictrorial Diagram DG1 PanelCircuitFigure S-3. Printed Wiring Board Cabinet Parts Parts ListParts marked * are used in voltage more than Electoric PartsRH-IXA222DRZZ LSI RH-IXA298DRZZ Eeprom Oven PartsSCRE,NUTS and Washers Door PartsMiscellaneous Model Number 2. REF. no Description HOW to Order Replacement PartsPacking and Accessories Oven and Cabinet Parts Control Panel Parts Door Parts Miscellaneous
Related manuals
Manual 32 pages 63.06 Kb

R-22AT, R-24AT specifications

The Sharp R-24AT and R-22AT microwave ovens are advanced kitchen appliances designed to enhance cooking convenience, efficiency, and versatility. Both models incorporate innovative technologies and features that cater to modern cooking needs.

The Sharp R-24AT boasts a robust 900 watts of cooking power, enabling users to prepare a wide variety of meals quickly and effectively. Its spacious 24-liter capacity is suitable for families and those who enjoy entertaining. One of the standout features of the R-24AT is its intelligent sensor technology, which automatically detects humidity levels in the cooking food. This innovative feature ensures optimal cooking times and temperatures, resulting in perfectly cooked dishes without the guesswork.

Another key technology in the R-24AT is the inverter cooking system. This system provides a seamless flow of power throughout the cooking process, allowing for more precise temperature control. Unlike traditional microwaves that operate in full power or off, inverter technology ensures consistent heat, which is particularly beneficial for tasks such as defrosting, reheating, and simmering.

The Sharp R-22AT, while slightly more compact with a 22-liter capacity, also delivers impressive performance with 800 watts of power. It features a similar inverter cooking system that guarantees even cooking results. Both models come with multiple auto-cook presets, providing users with a selection of quick options for common dishes such as popcorn, pizza, and oatmeal. This feature streamlines meal preparation and reduces the time spent on planning meals.

In addition, the user-friendly control panel on both models includes a combination of push-button and rotary dial controls for easy navigation. The inclusion of a bright LED display further enhances usability, allowing cooks to monitor cooking times and settings easily.

Safety is another critical aspect of the Sharp R-24AT and R-22AT. Both models come equipped with a child lock feature, ensuring peace of mind in homes with young children. The stainless steel interiors of these microwaves facilitate easy cleaning, while their sleek design adds a modern touch to any kitchen.

In summary, the Sharp R-24AT and R-22AT microwave ovens stand out for their advanced cooking technologies, user-friendly features, and thoughtful design. They empower home cooks to prepare meals with precision and ease, making them a valuable addition to any kitchen.