NEC NDA-24300 manual Designated Connection Test Procedure Register Test Procedure

Models: NDA-24300

1 653
Download 653 pages 50.84 Kb
Page 467
Image 467

SYSTEM OPERATIONS

(3)Designated Connection Test Procedure

(a)Register Test Procedure

Lift handset

(DT)

Dial access code for designated connection

“9xx

+

“xxx”

RT No.

 

 

TRK No.

 

 

 

 

 

 

 

 

(DT)

Dial “1,2,3,4,5,6,7,8,9,0” (*, # in case of PB signal) consecutively

(SST)

(NO)

Is next register to be tested, too?

(YES)

Make switch hook flash

Note

Access code is assigned by ASPA command, CI=N, SRV=SSC, SID=17

Route numbers to be designated are as follows.:

RT NUMBER

TRUNK NAME

902Originating Register Trunk

903Incoming Register Trunk

If any of the dialed numbers are not received correctly, a Reorder Tone (ROT) is heard.

Hang Up

TRUN K D ESIGNATIO N

TEST IN PRO GR ESS

 

 

 

 

 

REG ISTER

O RT

 

UND ER TEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: If the trunk number of the next register is not assigned, the test ends.

Figure 6-29 Register Test Procedure/Connection Diagram

CHAPTER 6

NDA-24300

Page 440

Issue 1

Page 467
Image 467
NEC NDA-24300 manual Designated Connection Test Procedure Register Test Procedure