SYSTEM MESSAGES

Lock-Up Failure (Permanent)

Default Alarm:

Default Grade:

Grade Modified:

Lamp Modified:

MN

3

 

 

 

 

 

 

At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the system displays this data. When the failure is detected more than 15 times per hour, the failure is judged as permanent.

1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4:

0000

0000

0000

0000

5:

0000

0000

0000

0000

6:

0000

0000

0000

0000

 

7:

0000

0000

0000

0000

8:

0000

0000

0000

0000

9:

0000

0000

0000

0000

 

 

 

 

 

 

 

 

 

 

 

Faulty Circuit Card Location

 

b0-b4: Group

 

 

 

 

 

 

 

b7

b6

b5

b4

b3

b2

b1

b0

b5-b6: Unit (0-3)

 

 

 

 

 

 

 

b7: Module Group

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0/1 = Even-numbered MG/Odd-numbered MG

Reference: See Chapter 5, Section 6.2, for the repair procedure.