SYSTEM OPERATIONS

12.1.5How to Control Switching Block

The Switching Block denoted here includes the following system equipment:

TSW (PH-SW12)

MUX (PH-PC36)

DLKC (PH-PC20)

PLO (PH-CK16/17/16-A/17-A)

ATTENTION

Contents Static Sensitive

Handling Precautions Required

Perform the required system changeover by using the CMOD command or by operating the relevant key on the GT/PLO card. Refer to Table 6-9.

Table 6-9 Changeover of Switching Block

Type

Operations

Remarks

 

 

 

Speech Path Changeover by the

Use CMOD command.

All OPE or ACT lamps on the

CMOD command

 

Speech Path System, which were

 

 

formerly active, go OFF.

 

 

All OPE or ACT lamps on the

 

 

Speech Path System, which were

Note

See Chapter 8.

formerly STBY, light steady-

 

 

green.

 

 

 

Speech Path System Changeover by

On active GT card, turn MBR key UP.

All OPE or ACT lamps on the

Key Operation on the active GT card

 

Speech Path System, which were

 

Return MBR key to original position (DOWN)

formerly active, go OFF.

 

after OPE/MB lamp goes OFF on GT card.

 

 

 

All OPE or ACT lamps on the

Note

See Section 12.1.6, Manual System Changeover

other side Speech Path System,

 

of Speech Path System.

light steady-green.

 

 

 

PLO Changeover by Key Operation

On active PLO card, turn MBR key UP.

ACT lamp on the PLO card, which

 

 

was formerly active, goes OFF.

 

Return MB key to original position (DOWN)

 

 

after ACT lamp goes OFF on PLO card.

ACT lamp on the PLO card, which

 

 

was formerly STBY, goes steady-

Note

See Section 12.1.7, Manual System Changeover

green.

 

of PLO.

 

 

 

 

Note: These operations cause a momentary interruption in speech paths. Since the interruption is momentary, it can be ignored as far as ordinary telephone calls are concerned. However, care should be take when data communications are involved, as the interruption might cause bit errors.