SYSTEM MESSAGES

4-T

Both MUX Ready Failure

Default Alarm:

Default Grade:

Grade Modified:

Lamp Modified:

MN

3

 

 

 

 

 

 

This message displays when the MUX (PH-PC36) card has a Ready Failure in both of the dual systems. When the card is not ready for service function because of the failure or because the card is not mounted properly, the system creates this system message.

1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000

4:0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000

7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000

Unit and MG number for MUX card with the ready fault

b7

b6

b5

b4

b3

b2

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0:

0/1 = -/MUX ready fault in even-numbered MG, Unit 0

b1:

0/1 = -/MUX ready fault in even-numbered MG, Unit 1

b2:

0/1 = -/MUX ready fault in even-numbered MG, Unit 2

b3:

0/1 = -/MUX ready fault in even-numbered MG, Unit 3

b4:

0/1 = -/MUX ready fault in odd-numbered MG, Unit 0

b5:

0/1 = -/MUX ready fault in odd-numbered MG, Unit 1

b6:

0/1 = -/MUX ready fault in odd-numbered MG, Unit 2

b7:

0/1 = -/MUX ready fault in odd-numbered MG, Unit 3

MG and system number for faulty MUX card

b7

b2

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0:

MG number for faulty MUX card

 

0/1 = Even number/Odd number

b1:

0/1 = Ready failure in MUX No. 0 system/Ready failure in MUX No.

 

1 system Note 1

b2:

ACT or STBY status of the faulty MUX Note 2

 

0/1 = ACT/STBY

Note 1: Though this message indicates the Ready Failure in both systems, the information displayed here only relates to the ACT-side MUX status. (Two messages are not displayed separately.)

Note 2: Fixed as “0 (=ACT).” See Note 1.

Reference: See Chapter 5, Section 4.3 and Section 4.4, for the repair procedure.