SYSTEM OPERATIONS

1.4Variable Alarm Indication

This feature allows PBX users to make a flexible change of system message output grades which range 0 to 3 and alarm lamp grades which consist of MJ, MN, SUP and NONE. Thus, the PBX users can give a proper alarm grade to each system message according to their requirements. When assigning no data, the default alarm grades are automatically adopted.

COMMAND

COMMAND FULL NAME

ALMG

Assignment of Alarm Grade Data

2.COLLECTION OF SYSTEM MESSAGES

System messages are collected in the following ways:

Automatic printout to the system message dedicated printer

Automatic printout to the MAT printer

Printout by DFTD command

2.1Automatic Printout to System Message Dedicated Printer

Figure 6-4shows the operating procedure.

Power on to printer.

Automatic

Printout Status

Is printout

stopped

temporarily?

If a message is registered, the contents will print out.

YES

Set printer port to Make-Busy

 

 

status using MBSM command.

NO

Figure 6-4 Automatic Printout to System Message Dedicated Printer Operating Procedure

COMMAND

COMMAND FULL NAME

MBSM

Make Busy of System Message Printout

NDA-24300CHAPTER 6

Page 393

Issue 1

Page 420
Image 420