SYSTEM OPERATIONS

4.LINE LOAD CONTROL

In the PBX, Line Load Control can be activated automatically or manually as a countermeasure against abnor- mal traffic congestion.

In the case of automatic control, the system automatically monitors an overloaded situation and restricts out- going calls from stations and incoming calls from trunks.

In the case of manual control, the operator at an Attendant/Desk Console or the MAT restricts outgoing calls from stations and incoming calls from trunks.

This section covers the following methods to activate Line Load Control:

Control by dialing an access code from the ATTCON/DESKCON

Control by entering command data from the MAT

System automatic monitoring

Operating Procedure

(1)Operations on the Attendant Console

By the operations on the ATTCON, restriction is effected on an outgoing call from a station having SFC in which the SFI = 16 (Line Load Control) of ASFC command is set as RES=0 (incoming calls to that station are allowed). For restricting incoming calls from a trunk, system data ASYD, SYS1, INDEX59, b0=1 should be assigned.

• Setting

Press LOOP key.

Dial the access code for setting Line Load Control.

(SST)

Press CANCEL key.

Lamp (Figure 6-8) on control panel lights.

System message [6-C] displays.

Figure 6-6 Line Load Control Operationson ATTCON—Setting