FAULT REPAIR PROCEDURES

4.1 Check Point

When repairing a unit fault, consider the following items:

(1)Speech paths and control paths in the unit are connected to line/trunks via the MUX circuit cards. Be sure to check the alarm lamps on the MUX circuit cards, and check to see if the front cable between each MUX circuit card and TSW circuit card is connected correctly. Figure 5-5and Figure 5-6show the block dia- gram within the unit.

(2)The MUX circuit cards are operating in the ACT/STBY modes under control of the CPU circuit. When the ACT-side CPU has detected a fault in the ACT-side MUX circuit card, CPU changeover is executed and the ACT/STBY mode of the Speech Path System is also changed over. When both of the MUX circuit cards have become faulty, all the lines/trunks in that unit are placed into make-busy state. (If a PFT circuit card is located in that specific unit, the PFT is activated.) Figure 5-7shows the location of the MUX cards.

(3)When both units in a specific PIM are faulty, it is possible that the PWR circuit card mounted in that spe- cific PIM is faulty. In such a case, refer to Section 8, Power Supply Fault.

MUX0

MUX1

Clock

Clock

(B)

(B)

 

To

To

TSW/INT

TSW/INT

Speech

Speech

Path

Path

(A)

(A)

Control of

Control of

CPU No. 0

CPU No. 1

ACT/STBY of

ACT/STBY of

CPU No. 0

CPU No. 1

PM

LC/TRK

Line/

 

Trunk

LC/TRK

Circuit Card

 

SYMBOLS

 

: Circuit Card

 

(A) : Control on ACT/STBY of Speech Path Systems

 

(B) : Control on ACT/STBY of Clock Systems

 

Figure 5-5 Unit Control Block Diagram (Dual Configuration)

CHAPTER 5

NDA-24300

Page 334

Issue 1

Page 361
Image 361
NEC NDA-24300 manual Unit Control Block Diagram Dual Configuration