CSCL: Continuous Change of Station Class

CSCL: Continuous Change of Station Class

1.Functional Outline

This command can change the station class information (TEC, RSC, SFC) en bloc by designating the range of the station number.

2.Parameters

Input Data

 

 

TN:

Tenant Number

 

STN(START):

First Station Number [0-9, #, * (Max. 6 digits)]

Note 1

STN(END):

Last Station Number [0-9, #, * (Max. 6 digits)]

Note 1

TEC(OLD):

Telephone Equipment Class before change [1-31]

Note 2, Note 3

TEC(NEW):

Telephone Equipment Class after change [1-31]

Note 2

RSC(OLD):

Route Restriction Class before change [0-15]

Note 3

RSC(NEW):

Route Restriction Class after change [0-15]

 

SFC(OLD):

Service Feature Class before change [0-15]

Note 3

SFC(NEW):

Service Feature Class after change [0-15]

 

Note 1: In the bottom part of the display, a check box is provided to determine whether to use "*" and "#" as a part of the Station Number. If necessary, check the box.

Note 2: Details on TEC (Telephone Equipment Class) are shown below:

1=DP (10pps)

2=PB

3=DP/PB

4=DP (20pps)

5-11=Not used

12=Dterm

13=Data Terminal via Dterm

14=Hot Line

15=CAS Line

16=Data Terminal via Data Module

17=Not used

18=Virtual Line Appearance (for Dterm Multi-Line)

19-22=Not used

23=ISDN Terminal

24-26=Not used

27=8 Conference Equipment

28-31=Not used

 

Note 3: If you want to change all classes of all specified stations, enter “**” for this parameter.

Buttons

 

Execute:

Click to make the input data valid.

Cancel:

Click to cancel the input data.

Exit:

Click to exit this command.

Display Data

 

STN:

Station Number

STATUS:

Data Entry Result

 

OK=Data Assignment is successful Note

Note: If not OK (i.e. the data entry is not successful), related error message is displayed here.