SYS1, INDEX89, 90 — Routine Diagnosis Items: The item corresponding to each bit is to execute once a day.

Single System Configuration

INDEX89

b0 — Main Memory Check (MM Program Memory)

 

 

0/1 = No/Yes

 

b1

— DM Check (DM = Data Memory)

 

 

0/1 = No/Yes

 

b4

— Trunk Ineffective Hold Check

 

 

0/1= No/Yes

 

b5

— Trunk Ineffective Hold Detection

 

 

0/1 = No/Yes

INDEX90

b1 — Backup of Call Forwarding, Individual Speed Data, Name Display Data, User

 

 

Assign Soft Key Data and Number Sharing Data to HDD (see Index 304)

 

 

0/1 = No/Yes

 

b3

— Residual Link Detection

 

 

0/1 = No/Yes

INDEX304

b0 — Individual Speed Calling Data Saving

 

 

0/1 = Out/In Service (This data is valid when SYS1, INDEX90, b1=1)

 

b1

— Call Forwarding Data Saving

 

 

0/1 = Out/In Service (This data is valid when SYS1, INDEX90, b1=1)

 

b3

— Name Display Data Saving

 

 

0/1 = Out/In Service (This data is valid when SYS1, INDEX90, b1=1)

 

b4

— User Assign Soft Key Data Saving

 

 

0/1 = Out/In Service (This data is valid when SYS1, INDEX90, b1=1)

 

b5

— Number Sharing Data Saving

 

 

0/1 = Out/In Service (This data is valid when SYS1, INDEX90, b1=1)

Dual System Configuration

INDEX89

b0 — Main Memory Check (MM Program Memory)

 

 

0/1 = No/Yes

 

b1

— DM Check (DM = Data Memory)

 

 

0/1 = No/Yes

 

b2

— TSW ACT/STBY Changeover for Dual Systems

 

 

0/1 = No/Yes

 

b3

— CPU ACT/STBY Changeover for Dual Systems

 

 

0/1 = No/Yes

 

b4

— Trunk Ineffective Hold Check

 

 

0/1 = No/Yes

 

b5

— Trunk Ineffective Hold Detection

 

 

0/1 = No/Yes

NDA-24300CHAPTER 6