DLSS_T: Display of Lock Out Station – Number – Telephone Number

DLSS_T: Display of Lock Out Station – Number – Telephone Number

1.Functional Outline

This command is used to print out stations in lockout state, by using Telephone Numbers. This command is available at NCN (for Fusion network) only.

2.Parameters

Input Data

 

 

TYPE:

Printout of all lockout stations

 

 

Printout of lockout stations by tenant

 

 

Printout of lockout stations within a specified range of station number

UGN:

User Group Number

Note 1, Note 2

Start TELN:

First Telephone Number (max. 16 digits)

Note 2

End TELN:

End Telephone Number (max. 16 digits)

Note 2

Note 1: This parameter is valid when “Type =Printout of lockout stations by tenant” is selected.

Note 2: This parameter is valid when “Type =Printout of lockout stations within a specified range of station number” is selected.

Display Data

 

FPC:

Fusion Point Code (1-253)

TN:

Tenant Number

Start STN:

First Physical Station Number

 

(max. 5 digits for Business/max. 6 digits for Hotel system)

End STN:

End Physical Station Number

 

(max. 5 digits for Business/max. 6 digits for Hotel system)

CNT:

Count

UGN:

User Group Number

TELN:

Telephone Number (max. 16 digits)

LENS:

Line Equipment Number

Buttons

 

Get:

Click to get information on the lockout status.

Exit:

Click to exit this command.