SYSTEM OPERATIONS

7.2.7Call Metering Information

The value of call metering from the Central Office is transmitted via the data from the 92nd byte to 95th byte.

BYTE

DATA

 

EXAMPLE

 

 

 

 

 

 

92

1000

 

5

 

 

 

 

 

WHEN 5200 METERING PULSES

93

100

 

2

 

ARE RECEIVED FROM C.O.

 

 

 

 

94

10

 

0

 

 

 

 

 

 

95

1

 

0

 

 

 

 

 

 

 

 

 

 

 

7.2.8Office Code of Calling (Called) Party and Billing Process Office

The 96th byte through 99th byte indicates the Office Code of Calling (Called) Party terminated via CCIS line.

The 100th byte through 103rd byte indicates the Office Code of the office processing centralized bill- ing for CCIS network.

Note: Office Code includes the CCIS line access code.

BYTE

96

97

98

99

100

101

102

103

DATA

1st DIGIT

2nd DIGIT

3rd DIGIT

4th DIGIT

1st DIGIT

2nd DIGIT

3rd DIGIT

4th DIGIT

OFFICE CODE OF CALLING (CALLED) PARTY

OFFICE CODE OF BILLING PROCESS OFFICE

EXAMPLE

8

1

2

SPACE

8

1

3

SPACE

OFFICE CODE = 812

OFFICE CODE = 813

CHAPTER 6

NDA-24300

Page 414

Issue 1

Page 441
Image 441
NEC NDA-24300 manual Call Metering Information