ALMG: Assignment of Alarm Grade Data

ALMG: Assignment of Alarm Grade Data

1.Functional Outline

This command is used to make a flexible change of system message output grades. Thus, the PBX user can give a proper alarm grade to each system message according to their requirements. When no data is assigned, the default alarm grades are automatically adopted.

Note: This command cannot change the alarm grade for system message “6-A.”

2.Parameters

Input data

FK:

Fault Message Kind (0-7, 10-17, 20-27, 30-37)

FI:

Fault Message Index (A-Z)

LMP:

Fault Message Lamp Data (0-3)

 

0=Lamp OFF

 

1=SUP Lamp ON

 

2=MN Lamp ON

 

3=MJ Lamp ON

GRD:

Printout Grade (0-3)

TYPE:

Listup Type

 

1=All Data

 

2=Changed Data

 

3=Default Data

SYSM GRD: System Message Output Grade

Note: 0=All Messages 1=Not Used

2=MN/MJ Grade Messages 3=MJ Grade Messages

Note: When using ALMG command for system message output grade assignment, be sure to set “ASYD, SYS 1, Index 91, b2 and b3 = 0, 0”. For more information, refer to the Office Data Specifications.