SYSTEM OPERATIONS

8.2Operating Procedure

1.Procedure for Set-up and Start

The procedure to set up and start the traffic measurement is as follows:

STEP 1

ASYD

ASYDN

STEP 2

ATRF

By using the ASYD/ASYDN command, assign the necessary system data as follows:

When performing traffic measurement on a node basis:

SYS1, INDEX8 (Number of Tenants)

SYS1, INDEX9 (Number of Attendant Consoles)

SYS1, INDEX47, bit 0 (Unit of Traffic Measurement): 0/1 = CCS/Erlang

• SYS1, INDEX47, bit 7 (Traffic Measurement Service): 0/1 = Out/In Service Assign “1.”

When performing traffic measurement on a network basis (via TCP/IP):

SYS1, INDEX8 (Number of Tenants)

SYS1, INDEX9 (Number of Attendant Consoles)

SYS1, INDEX47, bit 0 (Unit of Traffic Measurement): 0/1 = CCS/Erlang

• SYS1, INDEX47, bit 7 (Traffic Measurement Service): 0/1 = Out/In Service Assign “1.”

By using the ATRF/ATRFN command, assign the traffic measurement programs as follows:

When performing traffic measurement on a node basis:

Assign traffic measurement “TYPE” (Note), “PORT” number to be used, and the output “INTERVAL” and “Time (HOUR/MINUTE),” etc. For more details, see the ATRF command in CHAPTER 8.

ATRFN

When performing traffic measurement on a network basis (via TCP/IP):

Assign traffic measurement “TYPE” (Note), “PORT” number to be used, and the output “INTER- VAL” and “Time (HOUR/MINUTE),” etc. For more details, see the ATRF command in CHAP- TER 8.

Note: You can select one measurement “TYPE” at a time. If you need two or more measurement “TYPE,” repeat the same steps, following the entry of this command.

STEP 3: Terminate all the MAT commands.

An image of IPX “MAT Menu” is shown in Figure 6-21. Terminate all MAT commands, and make sure no commands are currently running via the “Processes” button.

STEP 4: Set the programmed Traffic Measurement in routine operation.

Click the “Scan New Alarms/Traffic” and “Collect New Alarms” buttons on the IPX “MAT Menu” (confirm the clicked buttons remain in the pressed state). Then, the Traffic Measurement is activated as programmed.

END