NEC NDA-24300 Dcon Display of Connection Status, Len Crt, Connection Route Number 1-1023 Note

Models: NDA-24300

1 653
Download 653 pages 50.84 Kb
Page 578
Image 578

DCON: Display of Connection Status

DCON: Display of Connection Status

1.Functional Outline

This command displays the connection status of the station and trunks. If the specified station or trunk is busy, the connected party is displayed.

2.Parameters

Input data

 

Type:

Kind of Connection Status (1-4)

 

1=Station of Connection Status

 

2=Trunk of Connection Status

 

3=LENS of Connection Status

 

4=Connection Trunk of Connection Status (Fusion Network)

TN:

Note 1

STN:

Maximum number of digits is 5 for Business system, and 6 for Hotel system. Note 1

RT:

Note 2

TK:

Note 2

LEN:

Note 3

C_RT:

Connection Route Number (1-1023) Note 4

C_TK:

Connection Trunk Number (1-4095) Note 4

Note 1: This data is valid when Type=1.

Note 2: This data is valid when Type=2.

Note 3: This data is valid when Type=3.

Note 4: This data is valid when Type=4.