UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE

B

ATTENTION

Contents

Static Sensitive

Handling

Precautions Required

• TSW ACT lamp on the new card goes OFF.

Set the MB key on the new card DOWN.

 

TSW ACT lamp on the new card

Set the TSW MBR key on the new card DOWN.

remains OFF.

 

 

 

MBR (on the active GT card)

 

 

 

 

1

2

Flip the MBR key on the active GT card. Confirm the

 

 

 

new TSW card functions normally.

 

 

 

 

System Changeover

 

 

 

 

• Replaced TSW: STBY to ACT

 

Mate TSW: ACT to STBY

 

 

 

 

 

 

Check the following lamp indications

 

on the Speech Path block to which the

 

new TSW card belongs and ensure that

 

they are all steady-green:

 

TSW ACT (TSW cards)

 

OPE/MB (DLKC card)

END

MUX ACT (MUX cards)

 

 

Check the following lamp indications

 

on the mate Speech Path block and en-

 

sure that they are all OFF:

 

TSW ACT (TSW cards)

 

OPE/MB (DLKC card)

 

MUX ACT (MUX cards)

Note: The system changeover of TSW card can be executed also by using the CMOD command. For details, refer to Chapter 8, Maintenance Commands.