4-S

SYSTEM MESSAGES

MUX Ready Failure

Default Alarm:

Default Grade:

Grade Modified:

Lamp Modified:

MN

3

 

 

 

 

 

 

This message displays when the MUX (PH-PC36) card has a Ready Failure in one of the dual systems. When the card is not ready for service function because of the failure or because the card is not mounted properly, the system creates this message.

1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000

4:0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000

7:

0000

0000

0000

0000

8:

0000

0000

0000

0000

9:

0000

0000

0000

0000

Unit and MG number for MUX card with ready fault

b7

b6

b5

b4

b3

b2

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0:

0/1 = -/MUX ready fault in even-numbered MG, Unit 0

b1:

0/1 = -/MUX ready fault in even-numbered MG, Unit 1

b2:

0/1 = -/MUX ready fault in even-numbered MG, Unit 2

b3:

0/1 = -/MUX ready fault in even-numbered MG, Unit 3

b4:

0/1 = -/MUX ready fault in odd-numbered MG, Unit 0

b5:

0/1 = -/MUX ready fault in odd-numbered MG, Unit 1

b6:

0/1 = -/MUX ready fault in odd-numbered MG, Unit 2

b7:

0/1 = -/MUX ready fault in odd-numbered MG, Unit 3

MG and system number for faulty MUX card

b7

b2

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0:

MG number for faulty MUX card

 

0/1 = Even number/Odd number

b1:

0/1 = Ready failure in MUX No. 0 system/Ready failure in MUX No.

 

1 system

b2:

ACT or STBY status of faulty MUX.

 

0/1 = ACT/STBY

Reference: See Chapter 5, Section 4.3 and Section 4.4, for the repair procedure.

NDA-24300CHAPTER 3

Page 81

Issue 1

Page 108
Image 108
NEC NDA-24300 manual MUX Ready Failure, ➀ Unit and MG number for MUX card with ready fault