Lenovo 8332 manual Drive carrier module faults, Dealing with hardware faults

Models: 8332

1 44
Download 44 pages 18.59 Kb
Page 38
Image 38
Drive carrier module faults

Table 15. Thermal cooling (continued)

Symptom

Cause

Action

 

 

 

1. Front operator's panel unit fault

If the internal temperature

1. Check to ensure that local

LED amber.

measured in the airflow

ambient environment temperature

through the enclosure

2. An amber LED is lit on one or

is below the upper 35°C (95°F)

exceeds a pre-set threshold,

more PSUs.

specification.

a thermal alarm sound.

2. Check the installation for any

 

 

 

 

 

airflow restrictions at either the

 

 

front or rear of the enclosure. A

 

 

minimum gap of 2.5 cm (1 inch)

 

 

at the front and 5 cm (2 inches)

 

 

mm at the rear is recommended.

 

 

3. Check for restrictions due to dust

 

 

build up; clean as appropriate.

 

 

4. Check for excessive re-circulation

 

 

of heated air from rear to front.

 

 

Use in a fully enclosed rack

 

 

installation is not recommended.

 

 

5. If possible, turn off the enclosure

 

 

and investigate the problem

 

 

before continuing.

 

 

 

Drive carrier module faults

Each Drive Carrier module has two LEDs: an upper (green) LED and a lower (amber) LED.

vUnder normal operation, the green LED is on and will flicker as the drive operates

vUnder normal operation, the amber LED will be:

Off if there is no drive present

Off as the drive operates

On if a drive fault is present

Dealing with hardware faults

Ensure that you have obtained a replacement module of the same type before removing any faulty module.

vIf the subsystem is powered up and you remove any module, replace it immediately. If the subsystem is used with modules or module blanks missing for more than a few minutes, the enclosure can overheat, causing power failure and data loss. Such use will invalidate the warranty.

vReplace a faulty drive with a drive of the same type and equal or greater capacity.

vRefer to your vendor-supplied documentation when using storage software for handling drive-related hardware faults.

vAll drive bays must be installed with a drive carrier module in order to maintain a balanced airflow.

vAll the supplied plug-in power supply units, electronics modules and blank modules must be in place for the air to flow correctly around the cabinet

30User Guide

Page 38
Image 38
Lenovo 8332 manual Drive carrier module faults, Dealing with hardware faults