SYSTEM MESSAGES

SMDR Output Buffer Overflow Alarm

Default Alarm:

Default Grade:

Grade Modified:

Lamp Modified:

SUP

1

 

 

 

 

 

 

This message displays when the SMDR output buffer usage rate has exceeded the value assigned to ASYD, SYS1, Index 249.

1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000

➁ ➂ ➃

4:0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000

7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000

Detail Information

b7 b6 b5 b4 b3 b2 b1 b0

(a) FS = 0, FE = 0/1

b7

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0-b3: FS

b4-b7: FE

This system message varies depending on the data.

 

FS

FE

MEANING

 

 

 

 

(a)

0

0

SMDR output buffer usage rate exceeds the value

 

 

 

assigned by ASYD, SYS1, Index 249.

 

 

 

 

(a)

0

1

After SMDR output buffer usage rate exceeds the

 

 

 

value assigned by ASYD, SYS1, Index 249, usage

 

 

 

rate lowered less than the value assigned by Index

 

 

 

250.

 

 

 

 

(b)

1

0

-

 

 

 

 

(c)

2

0

Data output is impossible due to SMDR apparatus

 

 

 

failure.

 

 

 

 

b0: 0/1 = Data assigned by the ASYD, SYS1, Index 249, 250 is valid/ invalid

NDA-24300CHAPTER 3

Page 105

Issue 1

Page 132