SYSTEM OPERATIONS

11.ROUTINE DIAGNOSIS

For confirming its own servicing status, the system automatically executes self diagnosis every day, and dis- plays the result of the diagnosis on a system message. By this function, possible causes for trouble can be dis- covered in an early stage and possible trouble can be prevented from remaining undetected.

11.1Related System Data

ASYD, SYS1, INDEX86,

b0 – When routine diagnosis starts, and the result of the routine diagnosis is normal, the result displays as system message [7-O].

0/1: Not displayed/To display

b1 – When the result of the routine diagnosis is abnormal, it displays as system message [7-P]. 0/1: Not displayed/To display

b3, b2 – Processing at the time when Trunk Ineffective Hold is detected. Note

Bit

 

Except the trunks being held on two-way calls

All trunks being held at

LENS of the trunk detected

 

 

 

(station-to-station call, station-to-trunk, trunk-

present are forcibly

display as system message

b3

 

b2

to-trunk call), the trunks being held at present

released

[7-P]

 

are forcibly released

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

X

X

0

 

1

X

1

 

0

X

X

 

 

 

 

 

 

Note: Trunk Ineffective Hold is a continuous state other than idle state within a predetermined duration while routine diagnosis is in progress. Whether it is to be detected/not detected is assigned by ASYD, SYS1, INDEX89.

SYS1, INDEX87, 88 - Routine Diagnosis Start Time

Start time should be such a time at which the traffic of the office is the lowest.

INDEX 87 0 2

INDEX 88 0 0

(Hour)

2:00 a.m. is the start time.

(Minute)

To stop the routine diagnosis, set FF respectively to INDEX87, 88.

CHAPTER 6

NDA-24300

Page 452

Issue 1

Page 479