SYSTEM MAINTENANCE OUTLINE

Table 2-2 Kinds of Circuit Card Front Restart

SENSE (0~F)

KIND OF RESTART

REMARKS

 

 

 

1

DM Clear Restart

 

 

 

 

2

DM Load Restart

When the system is in operation

 

 

 

5

OAI Memory Clear Restart

 

 

 

 

C

OFF-line Restart

 

 

 

 

PM (Line/Trunk Card) Make-Busy Restart

In this processing, the faulty PM (Line/Trunk Card) is isolated from the system and, at the same time, the calls associated with that faulty PM (Line/Trunk Card) are released. No calls related to the faulty PM (Line/Trunk Card) are processed and the system normally runs without the faulty PM (Line/Trunk Card).

Data Copy Restart

In a system of dual CPU configuration, the RAM memory (including the data memory) is copied from the ACT side CPU into the STBY side CPU, and ACT/STBY is changed over and monitor restart is executed.

In the case of this restart processing, only the ACT side CPU and the STBY side CPU are changed over without any effect on the current connections. However, no call processings are executed while the restart processing is in progress (from copying until the end of the changeover).

3.HOW TO READ PRECAUTIONS, DIAGNOSTIC, AND FAULT REPAIR INFORMATION

3.1Precaution about Diagnostic Procedure/Fault Repair Procedure

When performing diagnostic procedures/fault repair procedures, always adhere to the following actions:

(1)When replacing a circuit card with a spare, handle the circuit card using the Field Service Kit.

(a)To protect the circuit card from static electricity, wear a wrist strap before handling the circuit card.

(b)Before extracting the circuit card from its mounting slot, set its MB switch to the UP side (ON).

(2)When holding a circuit card by hand, wear gloves and be careful not to touch mounted parts, gold-plated terminal, etc., on the circuit card.

The 3MModel 8012 Portable Field Service Kit, shown in Figure 2-19, is recommended as an effective countermeasure against static electricity.