SYSTEM MESSAGES

1-T

TSW ACT Change Report

Default Alarm:

Default Grade:

Grade Modified:

Lamp Modified:

NON

2

 

 

 

 

 

 

This message displays when the changeover of the TSW system is executed.

1: XXXX 0000 XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 XXXX XXXX

 

➀ ➁

 

➂ ➃ ➄ ➅

 

 

 

 

 

 

 

➆ ➇ ➈ ➉

4:

0000

0000

0000

0000

5:

0000

0000

0000

0000

6:

0000

0000

0000

0000

7:

0000

0000

0000

0000

8:

0000

0000

0000

0000

9:

0000

0000

0000

0000

ACT side Speech Path (TSW) after changeover

b7

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reason for changeover

b7

b6

b5

b4

b3

b2

b1

b0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0:

0/1 = No. 0 system/No. 1 system

b7-b4

b3-b0

Card

Contents

 

 

 

 

0

1

TSW

I/O Alarm

 

 

 

 

 

2

 

32ch Clock down, FH down

 

 

 

 

 

3

 

24ch Clock down, FH down

 

 

 

 

 

6

 

TSW SW Memory write failure

 

 

 

 

 

9

 

I/O Alarm release

 

 

 

 

 

10

 

32ch Clock down recovered,

 

 

 

FH down recovered

 

 

 

 

 

11

 

24ch Clock down recovered,

 

 

 

FH down recovered

 

 

 

 

 

13

 

TSW MBR key OFF

 

 

 

 

 

15

 

TSW ACT/STBY changeover by CMOD

 

 

 

command

 

 

 

 

6

1

MUX

MUX circuit card Ready failure

 

 

 

 

 

2

 

MUX circuit card clock failure

 

 

 

 

CHAPTER 3