FAULT REPAIR PROCEDURES

6.3 Control System Fault - STBY Side Is Faulty

Faulty Situation:

Fault has occurred in the STBY side of dual configuration system.

[0-I] STBY CPU Failure

ATTENTION

Contents Static Sensitive

 

Handling

• The ACT side has become faulty, and system changeover has executed.

Precautions Required

 

[0-C], [0-H], [0-J] Processor Failure (ACT side)

START

Replace STBY side related circuit cards

 

 

Replace the circuit cards (CPU, GT, TSW,

 

 

(CPU, GT, TSW, MUX, EMA) with a spare,

 

 

MUX, EMA) individually by referring to the

and check.

 

 

following paragraphs in Chapter 4:

 

 

 

 

 

 

Section 1.3.1, CPR Replacement Procedure

 

 

 

 

 

 

 

 

 

 

 

 

Section 1.3.2, EMA Card Replacement

 

 

 

 

 

 

Procedure

 

 

 

 

 

 

Section 2.3.1, GT Card Replacement

 

 

 

 

 

 

Procedure

 

 

 

 

 

 

Section 2.3.2, TSW Card Replacement

 

 

 

 

 

 

Procedure

 

 

 

 

 

 

Section 3.3.2, MUX Card Replacement

 

 

 

 

 

 

Procedure

 

 

 

 

 

 

Place the circuit cards (CPU, GT, TSW, MUX)

 

 

 

 

 

 

 

 

 

 

 

 

into ACT mode by executing CPU changeover.

 

 

 

 

 

 

Refer to Section 12.1.6, Manual System

 

 

 

 

 

 

Changeover of Speech Path System, in Chapter

 

 

 

 

 

6.

 

 

 

 

 

 

Check to see if a station-to-station connection

 

 

 

 

 

 

 

 

 

 

 

 

can be set up to identify the circuit card

 

 

 

When a fault is not indicated, set

 

 

responsible for the fault.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the faulty systems to STBY side in

 

 

 

 

 

 

advance by executing CPU

 

 

 

 

 

 

changeover. Refer to Section 12,

 

 

 

 

 

 

System Control Procedures, in

 

 

 

 

 

 

Chapter 6.

 

 

 

END

NDA-24300CHAPTER 5

Page 361

Issue 1

Page 388
Image 388