ATRF: Assignment of Traffic Measurement Order

ATRF: Assignment of Traffic Measurement Order

1.Functional Outline

This command is used to assign and delete traffic measurement programs. A request for traffic measurement is performed when a traffic measurement instruction has been assigned by this command. The collected traffic measurement data can be stored on the HD of the MAT, which can be designated on the basis of traffic measurement type.

2.Parameters

Input Data

 

TYPE:

Type of Traffic Measurement (1-19) (See Table 8-2.)

 

 

 

Table 8-2 Type of Traffic Measurement Explanation

 

 

 

 

 

 

DATA

 

 

MEANING

DATA

MEANING

 

 

 

 

 

1

 

Terminal Traffic

2

Route Traffic

 

 

 

 

 

3

 

Station Peg Count

4

ATT Peg Count

 

 

 

 

 

5

 

Route Peg Count

6

Service Peg Count

 

 

 

 

 

8

 

UCD Route Peg Count

9

UCD Group Peg Count

 

 

 

 

 

10

 

UCD Station Peg Count

15

ATT Answering Peg Count

 

 

 

 

 

18

 

Connection Route Peg Count

19

Connection Route Traffic

 

 

 

 

 

 

PORT:

Traffic Information Output Terminal Number (0-7:IOC, 8:LAN, 9:NMS)

INTERVAL:

Output interval (0, 30-120)

 

Assign the data (30-120) in 10 minute increments. When assigning 0 (available

 

when any of TYPE 3-18 is selected), instead specify your desired output time in

 

the “OUTPUT HOUR/MINUTE” parameters below.

START HOUR

Note 1

START MINUTE

Note 1

END HOUR

Note 1

END MINUTE

Note 1

OUTPUT HOUR:

This data is valid only when INTERVAL=0.

OUTPUT MINUTE:

This data is valid only when INTERVAL= 0.

START RT:

Start External Route Number (available when TYPE 2/5/8 is selected)

END RT:

End External Route Number (available when TYPE 2/5/8 is selected)

START C_RT:

Start Connection Route Number (available when TYPE 18/19 is selected)

END C_RT:

End Connection Route Number (available when TYPE 18/19 is selected)

Note 1: Assign the traffic measurement time period between START HOUR/MINUTE and END HOUR/ MINUTE longer than an hour. Also, if the measurement should be executed throughout a day, assign the same data in both START HOUR/MINUTE and END HOUR/MINUTE parameters.

Note 2: Traffic Type 15 only works on Ring Down Trunks.