SYSTEM MESSAGES

Probable cause for failure

 

 

b0-b3: See Table.

 

 

b7

 

 

 

b3

b2

b1

b0

 

 

 

 

 

 

 

FLT ID

 

CCITT

FACTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ERROR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

 

A

S (F = 1) frame is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

 

B

DM (F = 1) response is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

 

C

UA (F = 1) response is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03

 

D

UA (F = 0) response is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04

 

E

DM (F = 0) response is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05

 

F

SABME command is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

06

 

G

N200 Timeout (Link is set)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07

 

H

N200 Timeout (Link is disconnected)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08

 

I

N200 Timeout (Link failure is restored

 

 

 

 

 

 

 

 

 

 

 

 

to normal)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09

 

J

N (R) frame error is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0A

 

K

FRMR frame is received (Link is re-set-

 

 

 

 

 

 

 

 

 

 

 

 

up).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0B

 

L

Undefined frame is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0C

 

M

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0D

 

N

Improper long frame is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0E

 

O

I frame with I field which exceeds

 

 

 

 

 

 

 

 

 

 

 

 

N201 is received.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0F

 

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

-

Layer 1 down (for ILC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

-

FRMR frame is received. (Link is not

 

 

 

 

 

 

 

 

 

 

 

 

re-setup)

 

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER 3

NDA-24300

Page 166

Issue 1

Page 193
Image 193