System Errors

System Errors

 

 

 

 

 

 

 

 

 

 

Code

Type

Description

Problem

Cause

Solution

EB00

Rec-

Stop Button

Record of a stop button

Indicates system stop

n/a

 

ord

Pressed

press.

key on ADM was

 

 

 

 

 

pressed.

 

EC00

Rec-

Setup

Record of changing

Indicates date and time

n/a

 

ord

Value(s)

setup variables.

when setup values

 

 

 

Changed

 

were changed.

 

EL00

Rec-

System

Record of power cycle

Indicates date and

n/a

 

ord

Power On

(ON).

time when system was

 

 

 

 

 

started.

 

EM00

Rec-

System

Record of power cycle

Indicates date and

n/a

 

ord

Power Off

(OFF).

time when system was

 

 

 

 

 

turned off.

 

EMIX

Advi-

Pump Off

The pumps are not

Pump power was

Start pumps by

 

sory

 

powered and are

turned off or an error

pressing pump start

 

 

 

unable to move.

occurred.

key on Advanced

 

 

 

 

 

Display module.

ES00

Advi-

Factory

Record of defaults

 

n/a

 

sory

Defaults

being loaded.

 

 

Communication Errors

NOTE: In some error codes listed below, a # symbol is shown as the last digit. This symbol represents the applicable component number, which can vary. The unit’s display will show the applicable number as the last digit in the code. For example, the CAC# code listed in this table will be displayed as CAC1 if the affected component is color change board 1, CAC2 for board 2, and so on.

Code

Type

Description

Problem

Cause

Solution

CA0X

Alarm

Comm. Error

System does not

This communication

Check CAN cable

 

 

ADM

detect the Advanced

error indicates that

connecting ADM to

 

 

 

Display Module

the Network has lost

the EFCM.

 

 

 

(ADM).

communication with

 

 

 

 

 

the Advanced Display

 

 

 

 

 

Module.

 

CAC#

Alarm

Comm. Error

System does not

This communication

Check CAN cable

 

 

Color Change

detect the Color

error indicates that

connections to

 

 

#

Change Module #.

the network has lost

the Color Change

 

 

 

 

communication with

Module # and any

 

 

 

 

the Color Change

interconnected

 

 

 

 

Module #.

modules.

CADX

Alarm

Comm. Error

System does not

This communication

Check CAN cables

 

 

Fluid Module

see the Enhanced

error indicates that

connecting ADM to

 

 

 

Fluid Control Module

the Network has lost

the EFCM. Replace

 

 

 

(EFCM).

communication with

Cable or EFCM as

 

 

 

 

the EFCM.

necessary.

332564B

95

Page 95
Image 95