Graco 332564B important safety instructions Read Recipe, Read Flush Sequence

Models: 332564B

1 104
Download 104 pages 58.79 Kb
Page 52
Image 52

Operation Using a Programmable Logic Controller (PLC)

Read Recipe

The Read Recipe command returns all configured recipe parameters for a desired recipe number. The number of the recipe to be read is the only argument.

Example: Read Recipe 5 data as it is currently configured with Color = 3, Catalyst = 2 (32), Color Flush Sequence = 1, Catalyst Flush Sequence = 4, Mix Ratio Set Point = 3.25:1, and Potlife = 35 min.

DCS Register

Parameter Description

Data

Units

Value

Range

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

DCS

Read Recipe

uint32

NONE

11

0

- 16

Command

 

 

 

 

 

 

Argument 0

Recipe #

uint32

NONE

5

0

- 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acknowledge

Command Acknowledged

uint32

NONE

2 = ACK

0

- 4

 

 

 

 

 

 

 

Return 0

Recipe #

uint32

NONE

5

0

- 60

 

 

 

 

 

 

 

Return 1

Material A

uint32

NONE

3

0

- 30, 61

 

 

 

 

 

 

Return 2

Material B

uint32

NONE

32

0, 31 - 34, 61

 

 

 

 

 

 

Return 3

Material A Flush Sequence

uint32

NONE

1

1 - 5

 

 

 

 

 

 

Return 4

Material B Flush Sequence

uint32

NONE

4

1 - 5

 

 

 

 

 

 

 

Return 5

Mix Ratio Set Point

uint32

NONE

325

0

- 5000

 

 

 

 

 

 

 

Return 6

Potlife Time Set Point

uint32

min

35

0

- 999

Read Flush Sequence

The Read Flush Sequence command returns all configured parameters for a desired flush sequence. The number of the flush sequence to be read is the only argument.

Example: Read Flush Sequence 1 as it is currently configured with Gun Purge Time = 20 sec, Initial Flush Volume = 0 cc, Final Flush Volume = 500 cc, Wash Cycles = 2, and Strokes per Cycle = 1.

DCS Register

Parameter Description

Data

Units

Value

Range

 

 

Type

 

 

 

 

DCS

Read Flush Sequence

uint32

NONE

12

0

- 16

Command

 

 

 

 

 

 

Argument 0

Flush Sequence #

uint32

NONE

1

1 - 5

 

 

 

 

 

 

 

Acknowledge

Command Acknowledged

uint32

NONE

2 = ACK

0

- 4

Return 0

Flush Sequence #

uint32

NONE

1

1 - 5

Return 1

Gun Purge Time

uint32

sec

20

0

- 999

Return 2

Initial Flush Volume

uint32

cc

0

0

- 9999

Return 3

Final Flush Volume

uint32

cc

500

0

- 9999

Return 4

# Wash Cycles

uint32

NONE

2

0

- 99

Return 5

Strokes per Wash Cycle

uint32

NONE

1

0

- 99

52