Setup
Connecting Lube Lines to Pump: Suction, Gravity and Pressure Fed Pump Models Only
NOTE: The lube line refers to the outlet line supplying lubricant to the lubrication points.
1.Apply thread sealant (user supplied) to lube line fit- ting.
2.Connect lube line to pump outlet (6), (FIG. 8)(also see pages 15 and 16).
3.Torque lube line fitting to 50 + 5 in. lbs (5.65 + 0.6 N.m).
If inst
6
FIG. 8
4.If installed, close the drain valve, located down- stream from the pump.
5.Hand prime the pump until clean,
6.Connect the lube line to the lube point.
7.After startup, adjust individual pumps to meet required flow rates. See Adjusting the Pump, page 8.
Alarm Models Only: Installing Pressure Sensor (see Alarm Pump, page 17)
1.Apply thread sealant (user supplied) to pressure sensor.
2.Install pressure sensor into sensor output (3) (FIG. 7).
NOTE: Sensor output will open at 100 - 200 psi (6.89 bar, 0.68 MPa).
3. After startup, ensure sensor is activating correctly.
Adjusting the Pump
I
Pump volume is controlled by an external adjusting screw (8) (FIG. 9). Turning the adjusting screw changes the length of the piston stroke which changes the pump discharge volume.
1. Loosen the adjusting screw locknut (9) (FIG. 9).
8
9
FIG. 9
2.Turn the adjusting screw (8) (FIG. 9):
•Counterclockwise - increases discharge volume (drops per stroke)
•Clockwise - decreases discharge volume (drops per stroke)