3.For Suction Fed and Gravity Fed models only: With the lubricator operating, count the drops from the drip tube (4) falling into the sight well (2) for one minute.
Calculating Pints per Day
4
2
FIG. 10
The number of drops seen falling in the sight well equals the amount of oil discharged by the pump. See Specifi- cations, page 10 for additional information on converting drops to volumetric output.
For Pressure Fed models only: Measure the output volume at the lube point.
4.If any further adjustment is necessary, repeat Steps 2 and 3.
5.Once the pump is adjusted to the proper specifica- tion, tighten the adjusting screw locknut (9) (FIG. 9).
NOTE: Piston stroke length set near zero may cause an inconsistent flow.
Calculating Minimum or Maximum Pump Output Capacity in Pints per Day
!" | % | ||||||
& | |||||||
|
| ||||||
#$ |
| '( |
| ||||
|
|
| & | ||||
|
|
|
|
|
| % | |
|
| ||||||
|
|
*Minimum and Maximum drops per stroke listed in Specifications, page 10.
Example:
The following example calculates the maximum and minimum flow for a 1/4 inch pump model with an electric motor and 300:1 gear ratio.
To calculate the Maximum Flow:
1725 RPM | X | Max 12 drops | X | 1440 min. |
| per stroke | |||
300:1 Gear Ratio |
|
| Max 6.88 | |
|
|
|
= Pints/day
14438(Number of Drops in a Pint)
To calculate the Minimum Flow:
Replace the maximum 12 drops per stroke (used in the equation above) with the minimum 2 drops per stroke = 1.17 minimum pints per day.