Maintenance

Maintenance

I

1

2

4

FIG. 11

Sight Well Fills With Oil

The oil level in the sight well (2) will rise and fall slightly during pump operation. Should the oil level in the sight well rise above the drip tube (4):

1.Remove the sight well plug (1).

2.Allow the pump to continue to operate until the oil level has dropped below the drip tube (4).

3.Clean sight well plug threads (1). Apply thread seal- ant (user supplied) to sight well plug.

4.Replace the sight well plug (1), taking care to not allow any thread sealant into the sight well (2).

5.Torque sight well plug (1) to 35 + 5 in. lbs (3.95 + 0.6 N.m).

Sight Well Runs Dry

Should the oil level in the sight well (2) fall below the pump body surface:

1.Remove the sight well plug (1).

2.Allow the pump to continue to operate and manually fill the sight well (2) with filtered oil to below the end of the drip tube (4).

3.Replace the sight well plug (1).

4.Torque sight well plug (1) to 35 + 5 in. lbs (3.95 + 0.6 N.m).

Sight Glass Replacement Kit

To replace a cloudy or broken sight glass in suction or gravity fed pumps, order GBL7500 Sight Glass Replace- ment Kit 24T306. See instruction manual 332560 included with Kit 24T306 for repair and replacement instructions.

Custom Socket Tool 16Y532

Used with the GBL7500 Sight Glass Replacement Kit for removing, tightening and torquing the Sight Glass Body

(5). See instruction manual 332560 included with Kit

24T306 for repair and replacement instructions.

12

3A2257C

Page 12
Image 12
Graco 24J392, 24J395, 24K466 Maintenance, Sight Well Fills With Oil, Sight Well Runs Dry, Sight Glass Replacement Kit